Sharp R8000 Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Mikrowellen Sharp R8000 herunter. Sharp R8000 Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - R-Series Instruction Manual

R-Series Instruction Manual Detector and Diverter Gate Northwest Marine Technology, Inc. 976 Ben Nevis Loop Road P.O. Box 427 Shaw Island, W

Seite 2

Detector Rear Panel The rear panel of the R-Series Detector has the tunnel exit, one or two air vent(s), an audio signal Alarm or (AudioLarm), a Ba

Seite 3 - Desiccant Cartridge Attached

R-Series Detector Rear Panel as of March 2002 Plugged lower vent “DRIERITE” cartridge installed Upper vent One end of hose attached to vent, other t

Seite 4 - Table of Contents

The Battery compartment holds two C-cell batteries; only Alkaline batteries should be used, since other types (regular, "heavy duty," rech

Seite 5

Diverter Gate The R-Series Diverter Gate attaches to the rear of the R-Series Detector and works in conjunction with it. Its main components are o

Seite 6 - Introduction

Gate Electronics Box The front side of the Gate Electronics Box has seven items: a Power Input Connector, a cable for connecting to the R Detector,

Seite 7 - Detector Front Panel

The Direction Switch is toggled to either the left or right. With the gate attached to the detector and the gate power on, set the direction switch

Seite 8

Rear view of Dual Counter with the Counter Cable with Sensors attached Counter Cable with Sensors Serial number is below the connector

Seite 9

Quad Counter The Quad Counter is used with the gate to keep track of the number of tagged and untagged fish in two different groups (sex, species e

Seite 10 - Detector Rear Panel

Part 3: Equipment Setup Detector Mounting and Setup In most cases, the R-Series detectors rely on gravity to transport fish through them and throug

Seite 11

Dual Counter Attachment The Dual Counter is mounted on the front handle of the Detector with 4 1/4-20X3/4” bolts and nylon insert nuts. The Counte

Seite 13 - Diverter Gate

Quad Counter cable connections. 1. The Counter Cable with Sensors connects to the connector at the rear face of the switch box. The sensors insta

Seite 14 - Gate Electronics Box

Cable attachments at Gate and Rear of Detector. Shown are: Battery connection to Gate, Quad Counter Power Cable connection to Det

Seite 15 - Dual Counter

R-Series Instruction Manual 22 Cable attachment

Seite 16 - Front Handle

Desiccant Cartridge R-Series detectors condense internal moisture when cold water is run through the tunnel. All detectors must have a functional

Seite 17 - Quad Counter

The “DRIERITE” cartridge contains 1.25 pounds of indicating CaSO4. When the desiccant is dry and active it is blue; when exhausted it turns pink.

Seite 18 - Part 3: Equipment Setup

3. Attach the brackets to the rear panel through the ¼ inch holes that are drilled in the top of the flange. Orient the brackets so that the tab

Seite 19 - Dual Counter Attachment

Hose clamp around 10” tubing and brass barb 6” tubing Electronics Connector 5. If it has become unattached, reattach the longer 10-inch piece of

Seite 20

Powering the Equipment 1) If the Detector is used with an attached Gate, connect either a 12 Volt Battery or the NMT R-Series120 VAC Power Supply

Seite 21

The NMT Power Supply should have a white label on the front dated November 2000. This is the only power supply that is authorized for use with the R

Seite 22

Aluminum Leg Assembly The tubular aluminum legs are shipped partially assembled, ready to bolt to the detector. If they are disassembled further,

Seite 23 - Desiccant Cartridge

R 9500 Detector with Gate, Dual Counter and Desiccant Cartridge Attached

Seite 24 - DRIERITE Desiccant Cartridge

Part 4: Detailed Operating Procedures Turning on Power This part presumes that the Equipment Setup section was followed so that the Detector, Gate

Seite 25

should be on approximately equal lengths of time, with the fourth lit occasionally. If it is known that no half-length tags will be in the fish, th

Seite 26

fish passing through the detector causes the Diverter Gate latch to toggle before the previous fish has completely exited the gate, and well before

Seite 27 - Powering the Equipment

are fully seated and at least one door is closed. You will note that holding one door open prevents the other side from counting. If the door is

Seite 28 - NMT Power Supply with Label

Part 5: Care and Maintenance The R-Series equipment is designed to be as rugged as possible while still being lightweight and performing as a preci

Seite 29 - Aluminum Leg Assembly

The Counter contains a lithium c-cell. The contents of the battery are considered hazardous materials and should be treated as such. Special atten

Seite 30 - Turning on Power

repair! . If you do not have one of these labels, and would like some please contact NMT. Magnets should not be allowed near the R-Series Detect

Seite 31

nearby with an electric drill or similar tool can also generate sufficient magnetic fields to disturb the detector. Wobble (rhythmic side to side o

Seite 32 - Counter Operation

Alarms and Signals Power Loss to Gate If the Detector is powered by an attached Diverter Gate, and has healthy C-cells installed, it will monitor

Seite 33

the latch hook. Retighten the lock nut, preferably with Locktite or some other anti-vibration solution. Part 7: Glossary Beak: The triangula

Seite 34 - Part 5: Care and Maintenance

Table of Contents Table of Contents...4 Introduction ...

Seite 35

Part 8: Appendix Daily Operation of the Detector with a Gate and Counter The following steps should be followed before each sampling session. Fo

Seite 36 - Part 6: Troubleshooting

8. Toggle the "Direction" switch several times to initialize the gate microprocessor. After toggling the switch, the latch hook should be

Seite 37 - Testing Sensitivity

15. Adjust the "Detector Sensitivity" so that the second and sometimes third LED in the bar graph is illuminated. Pass a CWT through the

Seite 38 - Adjustments

Daily Operation of the Detector without a Gate and Counter The following steps should be followed before each sampling session. For more detailed

Seite 39 - Part 7: Glossary

8. Adjust the "Detector Sensitivity" so that the second and sometimes third LED in the bar graph is illuminated. Pass a CWT through the d

Seite 40 - Part 8: Appendix

Detector Specifications Dimensions: The tunnels in the R8000 and R9500 are approximately rectangular. The R8000 tunnel’s inside dimensions are 4

Seite 41

R-Series Instruction Manual 46

Seite 42

Cleaning and Disinfecting of Equipment Soaps Sudbury Bilge Cleaner and Bio-Clean from VWR are two soaps that have been found to work well. Follow

Seite 43

The electronics connector allows input to the Detector of belt speed information to optimize sensitivity to belt speed and also automatically alter

Seite 44

Equipment Lists and Weights R-Series Detector  R- Series Detector Accessories:  Front handle with grip  Rear handle with grip  CWT Plug 

Seite 45 - Detector Specifications

Dimensions: ...45 Power Consumption...

Seite 46

Quad Counter  Quad Counter Switch Box  Dual Counter  Double Foot Switch  Tall front handle with grip  2 half handle brackets  4 ¼-20X

Seite 47

Contacting Northwest Marine Technology NMT strives to provide the highest quality tagging systems for research and management. We offer free consul

Seite 48

R-Series Instruction Manual 52 Telephone: +44-1725-512523,

Seite 49 - Equipment Lists and Weights

Introduction There are two models of R-Series Rectangular Tunnel Detectors, the R8000 and the R9500; they are designed to detect the presence of Co

Seite 50

Part 2: Equipment Description Detector Front Panel The front panel of the R-Series detector contains the entrance to the tunnel and the control pan

Seite 51 - Europe and Africa

attached, power is supplied from the Gate through the Electronics Connector on the rear panel. If used without a Gate, power may be supplied with ei

Seite 52 - South or Central America

condition of batteries, with one LED indicating very low charge and full scale indicating a fully charged battery. These LEDs stay lit from 10 to

Kommentare zu diesen Handbüchern

Keine Kommentare