8. DRAWER 1 OPEN & SENSOR TEST
8.1. Key operation
8.2. Test procedure
8.3. Check that:
The drawer 1 opens normally.
Always displays O (Opened), because XE-A40S doesn't have an
open sensor.
8.4. End of testing
You can exit the test mode by pressing any key. The printer prints the
following.
9. EXTERNAL RAM TEST
9.1. Key operation
9.2. Test procedure
The standard 256 Kbyte RAM is checked.
The contents of memory must be stored before and after this test.
RAM (08000H ~ 27FFFH area and 30000H ~ 4FFFFH area) is tested
in the following procedure:
1) Store data in the test areas
2) Write "00H"
3) Read and compare "00H" and then write"55H"
4) Read and compare "55H" and then write "AAH"
5) Read and compare "AAH"
6) Restore stored data
If an error occurs at a step, the error is printed.
If any error does not occur, the following addresses are checked in
turns.
Addresses to be checked:
9.3. Check:
The completion print.
9.4. End of testing
The program ends after printing as follows:
When an error occurs, the printer outputs the error message and the
address where the error has occurred in the area *****.
10. CPU INTERNAL RAM TEST
10.1. Key operation
10.2. Test procedure
The test program tests internal RAM (10 Kbytes) of the CPU.
The contents of memory must be stored before and after this test.
RAM (00400H ~ 02BFFH area) is tested in the following procedure.
1) Store data in the test area.
2) Write "00H"
3) Read and compare "00H" and then write "55H"
4) Read and compare "55H" and then write "AAH"
5) Read and compare "AAH"
6) Restore stored data
If an error occurs at a step, the error is printed.
If any error does not occur, the following addresses are checked in
turns.
Addresses to be checked:
10.3. Check:
The completion print.
10.4. End of testing
The test program ends after printing.
If an error occurs, the printer outputs the error message and the
address where the error has occurred in the area *****.
110 RCPT/PO
1 1 0
120 RCPT/PO
10000H , 10001H , 10002H , 10004H , 10008H ,
10010H , 10020H , 10040H , 10080H ,
10100H , 10200H , 10400H , 10800H ,
11000H , 12000H , 14000H , 18000H ,
20000H
30000H , 30001H , 30002H , 30004H , 30008H ,
30010H , 30020H , 30040H , 30080H ,
30100H , 30200H , 30400H , 30800H ,
31000H , 32000H , 34000H , 38000H ,
40000H
DRAWER
PGM
X
OP display
X:O=DRAWER OPENED
C = DRAWER CLOSED
1
RAM
PGM
OP display
120
When the test ends normally: 120
When the test end abnormally: Ex – – –
* * * * *
120
x = 1:Data error
x = 2:Address error
121 RCPT/PO
01000H , 01001H , 01002H , 01004H , 01008H
01010H , 01020H , 01040H , 01080H ,
01100H , 01200H , 01400H , 01800H ,
02000H
When the test ends normally: 121
When the test end abnormally: Ex – – –
* * * * *
121
x = 1:Data error
x = 2:Address error
RAMCPU
PGM
OP display
121