Sharp UP-820F Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Kassettendecks Sharp UP-820F herunter. Sharp UP-820F User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - COMMUNICATION SYSTEM

POS TERMINALINTER-REGISTERCOMMUNICATION SYSTEMUP-820FUP-820NMODEL

Seite 2

8In the IRC system, the following two types of clerk file systems are available: a centralized system and anindividual system. In the centralized cler

Seite 3 - TABLE OF CONTENTS

91) When the clerk signs on at a machine other than the one used in his or her previous operation:In this case, the overlapped clerk data is sent from

Seite 4

10The sign-on operation is intended to assign a clerk to a machine (satellite/master) and enable him or her tomake registrations at the machine.If a c

Seite 5 - Introduction

11A clerk sign-on report can be generated at the master. This report is used to know which clerks have signedon at which machines.Report generation pr

Seite 6 - Inline Operation

12The sign-off operation is intended to cancel the assignment of a clerk to a machine and terminate his or herregistration operation.The sign-off oper

Seite 7 - (2) Error messages

13When you have completed the programming at the master, you can distribute the preset data from themaster to all or desired satellites in the IRC sys

Seite 8

14(2) Maintenance downloadingTo update the preset data for the IRC system, follow the downloading procedure below. The presetdata in the master is dow

Seite 9

15List of downloading jobs (PGM2 mode)Downloading Jobs DescriptionDepartment preset dataDept./PLU key preset data for direct depts./PLUsPLU/EAN, link

Seite 10 - 4. Clerk system

16• The PLU/EAN file (INITIAL D/L and MAINTENANCE D/L) does not include stock data.• The OPTION file includes the following data:Optional feature pres

Seite 11

17In the IRC system, the following two types of GLU file allocation system are available: a centralized systemand an individual system.In choosing the

Seite 13 - 6. Clerk sign-on report

18In the IRC system, the following two systems for PLU/EAN stock control are available: a centralized systemand an individual system.In choosing the t

Seite 14 - 7. Sign-off operation

19All REG-mode transaction data in each satellite is saved in its T-LOG buffer. T-LOG polling is a datacollecting system in which the master collects

Seite 15 - (1) Initial downloading

20In the IRC system, the following two systems for PLU/EAN data control are available: a centralized systemand an individual system.In choosing the ty

Seite 16 - (2) Maintenance downloading

21(2) In case that the master has a dynamic EAN file and satellites don't:(3) In case that both the master and satellites have dynamic EAN files:

Seite 17

22When the price for an PLU/EAN item is changed at a machine (master or satellite), its PLU/EAN main file ordynamic PLU/EAN file is updated by the new

Seite 18

23When a remote printer is included in the inline system, order data is output to the remote printer accordingto the remote printer assignment.The rem

Seite 19

24In restaurants or the like, every terminal does not need an external printer (a bill printer, a validation printeror a kitchin printer).One external

Seite 20 - 10. PLU/EAN stock control

252Consolidated and Individual ReportsThe system can generate two types of sales reports: consolidated reports (reports on all or specifiedmachines in

Seite 21 - 11. T-LOG polling

26(1) Report generation procedureTo generate various reports, use the following procedure, referring to the list of consolidated reportson the followi

Seite 22 - 12. PLU/EAN data control

27(2) List of consolidated reports (SYSTEM READING/RESETTING)OPXZ X1/Z1 X2/Z2Report type DescriptionOperating modesRequired data/RemarksGeneral report

Seite 23

1TABLE OF CONTENTSIntroduction ·······················································································································

Seite 24 - 13. Price change function

28OPXZ X1/Z1 X2/Z2Report type DescriptionOperating modesRequired data/RemarksAll clerk reportIndividual clerk reportAll cashier reportIndividual cashi

Seite 25

29(1) Report generation procedureTo generate various reports, use the following procedure, referring to the list of individual reports onthe following

Seite 26 - 16. Rerouting print data

30(2) List of individual reports (READING/RESETTING)OPXZ X1/Z1 X2/Z2Report type DescriptionOperating modesRequired data/RemarksGeneral reportDepartmen

Seite 27 - 1. Operating modes

31OPXZ X1/Z1 X2/Z2Report type DescriptionOperating modesRequired data/RemarksAll clerk reportIndividual clerk reportAll cashier reportIndividual cashi

Seite 28

32In a system which has no save file and has been programmed so as to automatically lock the satellites afterresetting when general resetting, hourly

Seite 29

33As stated earlier (see page 8), there are two systems for collecting clerk sales data: a centralized systemand an individual system.(1) Centralized

Seite 30

34(2) Individual clerk file systemIn this system, you can generate full or individual clerk consolidated X or Z reports at the master only.At each mac

Seite 31

35The cashier file management method in the IRC system employs a non-centralized or individual system. Acashier who is assigned to a machine can carry

Seite 32

36Each machine can be programmed to enable the Compulsory Cash/Check Declaration (CCD) function. Thisfunction compels the operator to enter the cash/c

Seite 33

37Even when a machine has been programmed to disallow entries after full item total resetting or has notbeen programmed to allow automatic clearing op

Seite 34

2IRC Programming··································································································································381.

Seite 35 - 5. Clerk report

383IRC ProgrammingTo start IRC programming, first, turn on the machines in the IRC system and put them in the PGM2 mode.The programming procedures for

Seite 36 - Symbol of copy

39For the setup of your IRC system, please be sure to consult your authorized SHARP dealer.It is assumed that your IRC terminals have been set for inl

Seite 37 - 6. Cashier report

40For the setup of your IRC system, please be sure to consult your authorized SHARP dealer.(1) Setting the terminal number for the master and creating

Seite 38

41• The terminal numbers and machine numbers of the master and satellites must be entered intothe master list for IRC communications.• The terminal nu

Seite 39

42You can assign one satellite to the function of a back-up master. If the master fails during guest checkoperation, the assigned terminal will perfor

Seite 40 - IRC Programming

43You can specify whether to enable or disable the system retry function if a communication betweenmachines does not end successfully.This function ca

Seite 41

44At a satellite, you can choose which machine, either the master or the satellite, should be searched first forthe PLU/EAN code. If you specify that

Seite 42

451. Enter the PGM2 mode from the mode selection window.2. Select “READING” and press the ekey.The READING window will appear.3. Select “INLINE CONFIG

Seite 43

46Sample Print (master)Sample Print (satellite)Terminal number of the masterMWS port no.Terminal number of the satelliteMWS port no.System retry funct

Seite 44

47For connection of a remote printer to a terminal(s) in the IRC system, be sure to consult your authorizedSHARP dealer.(1) Basic programming for the

Seite 45

3IntroductionThe UP-820F/UP-820N inter-register communication (IRC) system consists of one master machine and upto 31 satellite machines which are all

Seite 46

48Items to be programmedTERMINAL#Enter the terminal number (1-254, 0).CHANNEL#Enter the channel number (0-7).PRINTERSelect the model of the remote pri

Seite 47

49(2) Optional programming for the remote printer – master and satelliteWith the following procedure, you can specify what items to be printed on the

Seite 48 - Sample Print (satellite)

50Items to be programmedSEPARATOR LINENO: Does not print the separator line on the remote printer.YES: Prints the separator line on the remote printer

Seite 49

51The LAN interface for the UP-820F/UP-820N POS enables the UP-820F/UP-820N to perform in-linecommunications to a host P.C. through the connection to

Seite 50

52(2) Programming of the time-out timeThe time-out value for receiving the data can be specified by the following procedure:1. Enter the PGM2 mode fro

Seite 51

531. Enter the PGM2 mode from the mode selection window.2. Select “READING” and press the ekey.The READING window will appear.3. Select “MWS CONFIG” a

Seite 52

544System Back-UpThe IRC system incorporates a back-up system.One of the satellites can be designated to serve as a back-up master.For the setup of a

Seite 53 - – master and satellite

55When the master or back-up master breaks down, the master declaration procedure should be taken toinform satellites of the breakdown.(1) When the ma

Seite 54

56The master declaration procedure is as follows:1. Enter the PGM2 mode from the mode selection window.2. Select “DECLARATION” and press the ekey.The

Seite 55 - GATEWAY No

57(2) When the back-up master breaks down – Master declaration at the masterFlow of a master declaration at the master1) A satellite detects a breakdo

Seite 56 - System Back-Up

41Inline Operation(1) Message displayed during inline communication1)The message as shown below is displayed at the master which is engaged in IRC tra

Seite 57 - 2. Master declaration

58When the master or back-up master recovers from a breakdown, the recovery declaration operation shouldbe taken to inform satellites of the recovery.

Seite 58

59The recovery declaration procedure is as follows:1. Enter the PGM2 mode from the mode selection window.2. Select “DECLARATION” and press the ekey.Th

Seite 59

60(2) When the back-up master recovers from a breakdown – Recoverydeclaration at the masterFlow of a recovery declaration at the master1) The recovery

Seite 60 - 3. Recovery declaration

615Error RecoveryWith the manual clear operation, you can clear various item memories when necessary. This operationshould be done only when the maste

Seite 61

62(2) List of manual clearing itemsManual clearing of the clerk sign-on stateManual clearing of the ‘GLU data in use’ stateManual clearing of the GENE

Seite 62

63If a transmission job from the master to a satellite is not performed successfully, the master eitherterminates the job immediately or awaits a comm

Seite 63 - Error Recovery

64(2) When the system retry function is enabledIf a transmission error relating to a satellite occurs, the relevant window will appear on the display

Seite 64

656BASIC SPECIFICATIONS for LANTransmission system: 10Base-T/100Base-TTransmission speed: 10 Mbits/sec / 100Mbits/secTransmission distance: Segment le

Seite 66

5(2) Error messagesIf an error occurs, a corresponding error message is displayed.To clear an error message, press the Lkey.For error messages, see th

Seite 67 - BASIC SPECIFICATIONS for LAN

6When the open store operation is performed at the master, the IRC system is opened. POS can send ATcommand by this job. This function controls a mode

Seite 68 - UP820F820NV_2IE10

7When the close store operation is performed at the master, the IRC system is closed. POS can send ATcommand by this job. This function controls a mod

Verwandte Modelle: UP-820N

Kommentare zu diesen Handbüchern

Keine Kommentare