Seitenansicht 34
33
STATUS
INDICATORS
MISFEED REMOVAL
Misfeed removal
2
Turn the roller rotating knob in the direction of the
arrow.
3
Carefully remove the misfed paper. Lower the fusing
unit release levers to allow easier removal. Return the
release levers to their operating positions.
The fusing unit is hot. Take care in removing paper.
Do not touch the surface of the drum (green portion)
of the drum cartridge when removing the misfed
paper. Doing so may damage the drum and cause
smudges on copies.
Be careful about unfixed toner on the misfed paper.
4
Close the front cover by pushing both sides with your
hands and then close the side cover by pressing the
handle on the cover.
The misfeed ( ) indicator will go out and the START key indicator
will light up.
When closing the covers, be sure to close the front
cover securely and then close the side cover. If the
covers are closed in the wrong order, the covers may
be damaged.
C. Misfeed in the transport area
1
Open the paper guide by pressing down the projection
on either side of the guide and remove the misfed paper.
The fusing unit is hot. Take care in removing paper.
2
If the misfed paper cannot be removed by the previous
step but is visible in the paper output area, remove the
paper by pulling it into the paper output area.
Roller rotating knob
Fusing unit release lever