24
R-21AT
Upper Oven
Hinge
Upper 
Oven
Hinge
Lower 
Oven
Hinge
Lower 
Oven
Hinge
Pin
Pin
Choke Cover
Door
Panel
5. Release choke cover from door panel.
6. Now choke cover is free.
Figure C-6. Door Disassembly
7. Release two (2) pins of door panel from two (2) holes
of upper and lower oven hinges by lifting up.
8. Now, door sub assembly is free from oven cavity.
DOOR PANEL REMOVAL
9. Remove the four (4) screws holding the door panel to
the door frame.
10.Release door panel from seven (7) tabs of door frame
by sliding door panel downward.
11.Now, the door panel is free.
DOOR HANDLE REMOVAL
12.Release the latch spring from the tab of the latch angle
assembly.
13.Remove the two (2) screws holding the door handle
and the latch angle assembly through the door frame.
14.Now, door handle is free.
LATCH HEADS REMOVAL
15.Remove the one (1) screw holding the latch angle
assembly to the door frame.
16.Remove the latch angle assembly together with the
latch lever, latch spring and the upper and lower latch
heads from the door frame.
17.Release the latch lever together with the latch spring
and the latch heads from the latch angle assembly.
18.Release the two (2) latch heads from the latch lever.
19.Now, the upper and lower latch heads are free.
FRONT DOOR GLASS REMOVAL
(After DOOR PANEL REMOVAL)
12.Remove the four (4) screws holding the glass stopper
U to the door frame and remove the glass stopper U.
13.Remove the two (2) screws holding the glass stopper
R to the door frame and remove the glass stopper R.
14.Slide the front door glass left at first and then slide
upwards to release it from the tabs holding it.
17.Now, the front door glass is free
DOOR CASE REMOVAL
(After DOOR PANEL REMOVAL)
12.Straighten all tabs of the door case holding the door
case to the door frame.
13.Release door case from the door frame.
17.Now, the door case is free
NOTE: At this moment, the door badge is attached on the
door case.
RE-INSTALL OF THE DOOR
1. Re-install all door parts except the choke cover.
2. Catch two (2) pins of door panel on two (2) holes of
upper and lower oven hinges.
3. Re-install choke cover to door panel by pushing.
NOTE: After any service to the door;
(A) Make sure that door sensing switch and second-
ary interlock switch are operating properly. (Re-
fer to chapter "Test Procedures".).
(B) An approved microwave survey meter should be
used to assure compliance with proper micro-
wave radiation emission limitation standards.
(Refer to Microwave Measurement Procedure.)
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through center of
latch hole.
2. Deviation of door alignment from horizontal line of
cavity face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Check for microwave leakage around door with an
approved microwave survey meter. (Refer to Micro-
wave Measurement Procedure.)
Note: The door on a microwave oven is designed to act as
an electronic seal preventing the leakage of micro-
wave energy from oven cavity during cook cycle.
This function does not require that the door be air-
tight, moisture (condensation)-tight or light-tight.
Therefore, occasional appearance of moisture, light
or sensing of gentle warm air movement around
oven door is not abnormal and do not in themselves
indicate a leakage of microwave energy from oven
cavity.
Putty Knife
Door Frame
Choke Cover