SmartPanel Projector Driver Application Note
Sharp XG-P20XU
© 2002 SP Controls Inc. 601 Minnesota Suite 115 San Francisco, CA 94107
III. TROUBLESHOOTING
Additional tips can be found in the SmartPanel Configuration and Installation Guide.
The Projector keeps turning itself off!
The Panel turns itself off when power verification indicates that the projector is off (see Note 1). Also, if
the Automatic Power Shut-Off Feature is on, the projector will shut itself off if it does not receive a signal
after fifteen minutes.
Check to make sure the RS-232 connection is correctly wired. If a third party power current
sensor is being used, make sure correctly wired and calibrated. The most common cause for
power polling failure when other control works, is that the RX line is incorrectly wired or soldered.
Verify that the P20XU’s Economy Mode Automatic Power Shut-Off Feature is set to OFF as
explained in the Special Control Note in Section V of this document.
Also verify that the MNTR Out/RS232C is set to OFF as explained in the Special Control Note in
Section V of this document. If this setting is incorrect, the Sharp will not respond to SmartPanel
power polling and the Panel will shut itself off (see next note and Note 1 below).
The Panel does not do anything at all.
When power is applied to the Panel it should run through a brief power on self-test, during which all of
the Panel lights will turn on and off in sequence. If you do not see this self-test, make sure power is
connected correctly and that polarity is correct.
The Panel has only partial control over the Sharp.
Verify that both RS-232 and the wired remote are correctly wired. The most common error is reversal
of RX and TX for RS232, and polarity reversal of the wired remote. Note that the Sharp is controlled
using both Wired Remote and RS-232. If a subset of functionality appears to be working, verify that
both types of control wiring are correctly wired.
Also, be sure that the Wired Remote port is manually set to “IR” and not to “Gyro” on the projector
and that pins 7 and 8 are jumpered on the female DB9.
IV. TECHNICAL NOTES
1. By default, projector power is verified by polling every few seconds via the RS-232 port. Power
polling can be suspended by depressing and holding the On key; polling will be restored when the
key is released. Should the Sharp power off, the Panel will usually detect this condition and power
off within twenty seconds. Should the Sharp power on, the Panel will usually detecting this condition
and power on within ten seconds.
2. The Sharp is controlled via RS-232 and wired remote. The Sharp can alternately be controlled with
RS-232 and IR emitter. A discussion of the advantages of Wired Remote versus IR can be found in
the SmartPanel Configuration and Installation Guide.
3. The lockout timer specifies the amount of time allowed between sending POWER OFF and POWER
ON to the projector (the delay allows the projector bulb to cool before re-powering). This delay can
be configured using the Configuration Utility; however, adjusting the lockout timer delay is
strongly discouraged as rapid re-powering causes undue wear on the projector’s bulb. Also, the
Sharp will not allow power to be restored before a minimum delay has expired. Therefore, disabling
the lockout delay will cause potentially confusing Panel behavior.