FLIR E40 (incl. Wi-Fi)
Data communication interfaces
P/N: 49001-2001
Wi-Fi Peer to peer (adhoc) or infrastructure (network)
© 2014, FLIR Systems, Inc.
All rights reserved worldwide.
SD Card One card slot for removable SD memory cards
Audio Microphone headset via Bluetooth for voice annotation of
images
USB USB-A: Connect external USB device
USB Mini-B: Data transfer to and from PC / Uncom-
pressed colorized video
USB, standard USB Mini-B: 2.0
USB, connector type USB-A connector
USB Mini-B connector
Composite video
Video out Composite
Video, standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Video, connector type 4-pole 3.5 mm jack
Radio
Wi-Fi Standard: 802.11 b/g
Frequency range: 2412–2462 MHz
Max output power: 15 dBm
Bluetooth Frequency range: 2402–2480 MHz
Antenna Internal
Power system
Battery type Rechargeable Li Ion battery
Battery voltage 3.7 V
Battery capacity 4.4 Ah, at +20°C to +25°C (+68°F to +77°F)
Battery operating time Approx. 4 hours at +25°C (+77°F) ambient temperature and
typical use
Charging system In camera (AC adapter or 12 V from a vehicle) or 2-bay
charger
Charging time 4 h to 90% capacity, charging status indicated by LED's
Charging temperature 0°C to +45°C (+32°F to +113°F)
Power management Automatic shutdown and sleep mode (user selectable)
AC operation AC adapter, 90–260 VAC input, 12 V output to camera
Start-up time from sleep mode Instant on
Environmental data
Operating temperature range –15°C to +50°C (+5° F to +122°F)
Storage temperature range –40°C to +70°C (–40°F to +158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
(+77°F to +104°F) / 2 cycles
EMC ETSI EN 301 489-1 (radio)
ETSI EN 301 489-17
EN 61000-6-2 (Immunity)
EN 61000-6-3 (Emission)
FCC 47 CFR Part 15 B (Emission)
ICES-003
Radio spectrum ETSI EN 300 328
FCC Part 15.247
RSS-210
Magnetic fields EN 61 000-4-8, Test level 5 for continous field (Severe
industrial environment)
Encapsulation IP 54 (IEC 60529)
Bump 25 g (IEC 60068-2-29)
Vibration 2 g (IEC 60068-2-6)
Safety EN/UL/CSA/PSE 60950-1