Sharp R-220KW(D) Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Mikrowellen Sharp R-220KW(D) herunter. Sharp R-220KW(D) Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Instruction Manual
DB Unit
Dynamic Braking Unit
200V Series
37kW /BU37-2C
to 90kW /BU90-2C
400V Series
37kW /BU37-4C
to 220kW /BU220-4C
CAUTION
Ensure that this instruction manual is made
available to the final user of the DB unit.
Read and understand all operating instructions
before installing, connecting (wiring), operating,
maintaining or inspecting the DB unit.
Keep this manual up to disposing the DB unit
carefully.
The product is subject to change without notice.
INR-HF51196c-E
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Instruction Manual

Instruction Manual DB Unit Dynamic Braking Unit 200V Series 37kW /BU37-2C to 90kW /BU90-2C 400V Series 37kW /BU37-4C to 220kW /BU220-4C  CAUTIO

Seite 2 - Preface

1-2 1-3 Handling of the product (1) Removing the front cover Loosen the mounting screws of front cover and remove the front cover by hol

Seite 3 - Instruction on installation

2-1 DB UnitTopBottom 100mmRightLeft100m m50mmor more50mmor more 2 Installation and Connection 2-1 Operating environment Install the DB unit in

Seite 4 - Instruction on operation

2-2 2-3 Connection When removing the front cover, the terminal blocks appear (see Fig. 2-3-1). Connect the cables without mistake cari

Seite 5 - GENERAL ATTENTION

2-3 Basic connection diagram Basic connection diagram Basic connection diagram Basic connection diagram 1) In case of using one DB unit and o

Seite 6 - CAUTION

2-4 2-3-2 Connecting the main circuit and grounding terminals Table 2-3-1Functions of the main circuit terminals and grounding terminal Terminal mark

Seite 7

2-5 2-3-3 Connecting the control terminals Function descriptions of the control terminals are shown in Table 2-3-3. Table 2-3-3 Terminal marking Name

Seite 8 - Contents

2-6 (5) Wiring of the control circuit ① Lead out the cable along the left side panel as shown in Fig. 2-3-5. ② Secure the cable to cable-tie holder

Seite 9 - 1-2 Appearance

2-7 2-3-4 Terminal arrangement (1) Main circuit terminals BU37-2C Screw size M5 Screw size M5 BU220-4C Screw size M10 BU37-4C Screw size M4

Seite 10 - 1-5 Storage

2-8 2-3-5 Applicable devices and wire size as standard DB unit Braking resistor Tightening torque (N・m) Recommended wire size (mm2) ∗1) Voltage App

Seite 11 - 2-2 Installation Method

3-1 3 Operation 3-1 Inspection and preparation before operation Inspect the following items before operation ① Check that the connection is correct

Seite 12 - 2-3 Connection

Preface Thank you for purchasing our dynamic braking unit (DB unit). This product is a device to discharge the braking power to a resistor in a

Seite 13 - Wire length

4-1 4 Protective Operation 4-1 Protective operations In the event of abnormality as shown in Table 4-1, the DB unit stops DB driving signal and outp

Seite 14 -  CAUTION

5-1 5 Maintenance and Inspection Proceed with the daily inspection and periodic inspection to prevent malfunction and ensure long-term reliability.

Seite 15

5-2 (continued) Is there unusual odor or damage to the insulation by overheating? Olfactory and visual inspection Not abnormal Main circuit Resistor I

Seite 16

5-3 5-4 Parts replacement Each part has a life determined by the sort of the part. Since the life expectancy of a part differs depending on

Seite 18 - N(-),P(+)R,DB)

6-1 6 Specifications 6-1 Standard specifications 6-1-1 DB unit Series 200V 400V Type BU37-2C BU55-2C BU90-2C BU37-4C BU55-4C BU90-4C BU132-4C BU220

Seite 19 -  G, P(+), N(-), P(+)R, DB

6-2 6-1-2 Braking resistor 200V series Type DB30-2C DB37-2C DB45-2C DB55-2C DB75-2C DB110-2C Nominal applied motor (kW) 30 37 45 55 75 90,110 Re

Seite 20 -  WARNING

6-3 6-2 Outline dimensions 6-2-1 DB unit W 1ØCW 2CHH1H2H3H4DD13-取付ボルトHOLE S FO RFIXING BOLTSW 3W 2H1取付寸法MOUNTIN G D IM EN SIO NSW WW 2CHH1H2H3H4DD14

Seite 21

6-4 6-2-2 Braking resistor 4- φ C FIG. A FIG. B 4- φ C Control circuit Terminal Main circuit Terminal W W 1 H D 1 D W W 1 H H 1 D 1 D 1. 6 Main circ

Seite 22 - 5-3 Insulation test

7777----1111 7 Option Fan In this DB unit, the braking time and duty factor can be rise by using option fans. Standard specification When using op

Seite 23 - 5-4 Parts replacement

Instruction on installation  WARNING ・ Mount this DB unit on an material such as metal. Fire may result. ・ Do not place combustible or flammable m

Seite 24

7777----2222 7-3 Dimensions 7-3-1 Option fan unit W6 W5W DD3 D1H6HH7W4D2H5LFAN UNIT DB UNIT + FAN UNIT [Fan unit] DIMENSIONS [mm] TYPE W4

Seite 25 - 6-1 Standard specifications

Edition history Edition Date of issue Content – Sep. 1999 First edition a Oct. 2001 Correct : Section 2 Fig 2-3-3(Terminal Name) b Oct. 2003 Change

Seite 26 - 6-1-2 Braking resistor

2 Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome Shinagawa-ku, Tokyo 141-0032, Japan Phon

Seite 27 - [400 V series]

Instruction on operation  WARNING ・ Ensure that the power is turned on (close) after attaching the front cover. In energized status

Seite 28 - [400V series]

Instruction on disposal  CAUTION ・ Treat the DB unit as industrial waste when disposing it. Injury may result. Other instructions  WARNING ・ N

Seite 29 - 7-2-2 Wiring (Fig. 7-2-2)

Compliance with UL/cUL standards [[[[Applicable to products with UL/cUL mark]]]] 1.General UL(Underwriters Laboratories Inc.) standards is safety

Seite 30 - 7-3-1 Option fan unit

CAUTION Tightening torque and wire range 1.60℃/75℃ copper wire 2. 90℃ copper wire DB Unit B

Seite 31 - Edition history

Contents 1 Before Using This Product 1-1 Inspection at receiving the unit 1-1 1-2 Appearance 1-1 1-3 Handling of the product 1-2 1-4 Carrying

Seite 32

1-1 Front coverUnder of Unit(Mounting bord) Fig. 1-1-1 Ratings nameplate 1 Before Using This Product 1-1 Inspection at receiving the unit Unpack an