
_ _
3.4.2
CW.Signal
Gcncration
a.
S
et
the
CARmER
FREQUENCY
SELECTOR
to
the
desired
carrier
frequency.
b.
Place
the
function
switch
in
the
HARM.
AMP.
TUNING
position
and
adjust
the
HARM.
AMP.
TUNING
control
for
a
maximum
reading
on
the
FREQUENCY
meter.
The
HARM.
AMP.
TUNING
control
should
indicate
approximately
the
appropriate
number
recorded
on
the
Channel
Frequency
Chart.
c.
Place
the
function
switch
in
the
CW
position
and
z
ero
(mid-scale)
the
FREQUENCY
meter
with
the
CAL.
control
(inner
red
knob).
d.
Adjust
the
LEVEL
SET
control
to
the
SIG. GEN.
SET
LEVEL
number
listed
on
the
Channel
Fre-
quency
Chart
for
the
desired
car-
rier
frequency.
When
the
CE-7
is
directly
con-
nected
(via
the
20-dB
fixed
at-
tenuato
r) to a
transceiver,
its
transmitter
should
NEVER
be
keyed.
Any
input
in
excess
of
2
watts
will blow
the
fuse
in
the
20-dB
fixed
attenuator
and
may
damage
the
instrument.
e.
A
coaxial
cable
with
a
20-dB
fixed
attenuator
is
stored
inside
the
instrument's
front
cover
;
connect
the
cable
to
the
front-
panel
connector
marked
SIGNAL
GENERATOR
OUTPUT.
The
stgnat-gen
er
ator
attenuator
set-
tings
are
only
valid
if
the
20-dB
fixed
attenuator
is
used.
f.
The
desired
frequency
is
now
being
generated.
The
output
level
can
be
adjusted
by
means
of
the
Xl,
XIO,
XIOO
(Multiplier)
and
MICROV
OLTS
(Attenuator
Vernier)
controls.
'3.4.3
a.
b.
c.
d.
e.
FM-Signal
Generalion
Perform
steps
3.4.
2a
through
f.
These
steps
calibrate
the
CE-7
in
preparation
for
FM
signal
generation
.
1
4
" 4
Place
the
function
switch
in
the
FM
position.
I:
Set
the
DEV.
ADJ.
control
fully
~
counterclockwise.
I
-~
Zero
(mid-scale)
the
FREQUENCY
•
meter
with
the
FM
CAL.
control
(inner
red
knob).
I:
Set
the
FM
MOD.
switch
to
INT.
or
EXT.
as
desired.
In
the
I:
INT.
position
the
modulating
frequency
will
be 1 kHz;
exter-
41!!
nal
modulation
frequencies
can
I~
,
be
applied
through
the
BNC
connector
when
the
switch
is
in
the
EXT.
position.
When
the
FM
MOD.
switch
is
in
the
INT.
I:
position,
the
1
kHz
signal
is
avail-
~
able
at
the
1 k Hz OUT
connector.
The
level
of
the
1 kHz OUT
is
[,
adjusted
with
the
DEV.
ADJ.
,
control,
which
is
also
used
to
set
the
level
of
external
modulation
[~
applied
to
the
EXT.
connector.
,
NOTE
[:
The
FREQUENCY
meter
will
now
show
the
modulator
center
fre-
f!
quency
and
the
FM
Deviation
l\leter
[w
or
Oscilloscope
will
now
indicate
the
amount
of
deviation
of
the
gen-
•
erated
modulation.
The
FM
CAL.
lW
control
varies
the
center
freq
uency
ofthe
FM
signal
and
permits
testing
•
of
receivers
for
alignment
and
max-
imum
sens
itivity.
The
FREQUENCY
[.
meter
is
automatically
in
the
±5. 0
kHz
range
when
the
function
switch
is
in
the
FM
position,
and
it
cannot
"
[w
be
changed
by
the
±kHz
(FREQUENCY
lever)
.
•
3-6
5601"0015"1
- - - . -- - . -- - -
Kommentare zu diesen Handbüchern