Sharp R-320HQ Operation Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Mikrowellen Sharp R-320HQ Operation herunter. Sharp R-320HQ Operation Service manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
39
R-320HK
R-320HQ
R-320HW
In the interest of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con-
tain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe,
possibly fatal, electrical shock. (High Voltage Capacitor, High
Voltage Power Transformer, Magnetron, High Voltage Recti-
fier Assembly, High Voltage Harness etc..)
TABLE OF CONTENTS
Page
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO
AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY ...................INSIDE FRONT COVER
BEFORE SERVICING ......................................................................................................INSIDE FRONT COVER
WARNING TO SERVICE PERSONNEL................................................................................................................ 1
MICROWAVE MEASUREMENT PROCEDURE ................................................................................................... 2
FOREWORD AND WARNING............................................................................................................................... 3
PRODUCT SPECIFICATIONS .............................................................................................................................. 4
GENERAL INFORMATION................................................................................................................................... 4
OPERATION .......................................................................................................................................................... 6
TROUBLESHOOTING GUIDE ............................................................................................................................ 10
TEST PROCEDURE ............................................................................................................................................ 11
TOUCH CONTROL PANEL ................................................................................................................................. 20
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE ................................................................ 25
PICTORIAL DIAGRAM ........................................................................................................................................ 31
CONTROL UNIT CIRCUIT .................................................................................................................................. 32
PRINTED WIRING BOARD .................................................................................................................................33
PARTS LIST ........................................................................................................................................................ 34
PACKING AND ACCESSORIES ......................................................................................................................... 38
S4309R320HPW/
R-320HK
R-320HQ
R-320HW
MICROWAVE OVEN
MODELS
SERVICE MANUAL
SHARP CORPORATION
This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - SERVICE MANUAL

39R-320HKR-320HQR-320HWIn the interest of user-safety the oven should be restored to its originalcondition and only parts identical to those specified

Seite 2 - BEFORE SERVICING

8R-320HKR-320HQR-320HWSCHEMATICNOTE: CONDITION OF OVEN1. DOOR CLOSED2. COOKING TIME PROGRAMMED3. VARIABLE COOKING CONTROL "HIGH" (100%)4. &q

Seite 3 - WARNING TO SERVICE PERSONNEL

9R-320HKR-320HQR-320HWDESCRIPTION AND FUNCTION OF COMPONENTSDOOR OPEN MECHANISMThe door is opened by pushing the open button on thecontrol panel, refe

Seite 4

10R-320HKR-320HQR-320HWTROUBLESHOOTING GUIDENever touch any part in the circuit with your hand or an uninsulated tool while the power supply is connec

Seite 5 - SERVICE MANUAL

11R-320HKR-320HQR-320HWHome fuse or circuit breaker blowswhen power cord is plugged into wallreceptacleC/T fuse blows when power cord isplugged into w

Seite 6 - GENERAL INFORMATION

12R-320HKR-320HQR-320HWA MAGNETRON ASSEMBLY TESTTEST PROCEDURESPROCEDURELETTERCOMPONENT TEST1. Disconnect the power supply cord, and then remove outer

Seite 7 - OVEN DIAGRAM

13R-320HKR-320HQR-320HWC HIGH VOLTAGE RECTIFIER TEST1. Disconnect the power supply cord, and then remove outer case.2. Open the door and block it open

Seite 8 - OPERATION

14R-320HKR-320HQR-320HW1. Disconnect the power supply cord, and then remove outer case.2. Open the door and block it open.3. Discharge high voltage ca

Seite 9 - MICROWAVE

15R-320HKR-320HQR-320HWTEST PROCEDURESPROCEDURELETTERCOMPONENT TESTCAUTION: BEFORE REPLACING A BLOWN C/T FUSE, TEST THE PRIMARY INTERLOCK RELAY,SECOND

Seite 10 - MONITOR

16R-320HKR-320HQR-320HWTEST PROCEDURESPROCEDURELETTERCOMPONENT TEST3. If the Key unit or the Control unit is defective.1) Disconnect the power supply

Seite 11

17R-320HKR-320HQR-320HWRY1 and RY2 Relay TestThese relays are operated by D.C. voltageCheck voltage at the relay coil with a D.C. voltmeter during the

Seite 12 - TROUBLESHOOTING GUIDE

40R-320HKR-320HQR-320HWPRECAUTIONS TO BE OBSERVED BEFORE ANDDURING SERVICING TO AVOID POSSIBLEEXPOSURE TO EXCESSIVE MICROWAVEENERGY(a) Do not operate

Seite 13 - DEFECTIVE PARTS

18R-320HKR-320HQR-320HWTEST PROCEDURESPROCEDURELETTERCOMPONENT TEST1) Disconnect the power supply cord, and then remove outer case.2) Open the door an

Seite 14 - TEST PROCEDURES

19R-320HKR-320HQR-320HWTEST PROCEDURESPROCEDURELETTERCOMPONENT TESTTESTING METHOD FOR AH SENSOR AND/OR CONTROL UNITTo determine if the sensor is defec

Seite 15

20R-320HKR-320HQR-320HWDESCRIPTION OF LSILSIThe I/O signal of the LSI is detailed in the following table.TOUCH CONTROL PANEL ASSEMBLYOUTLINE OF TOUCH

Seite 16

21R-320HKR-320HQR-320HWPin No. Signal I/O Description9 AN1 IN AH sensor input.This input is an analog input terminal from the AH sensor circuit, and c

Seite 17

22R-320HKR-320HQR-320HW33 P27 OUT Key strobe signal.Signal applied to touch-key section. A pulse signal is input to P70, P71, P41, P45, P47 andAN3 ter

Seite 18

23R-320HKR-320HQR-320HWPin No. Signal I/O Description79 COM0 OUT Common data signal.Connected to LCD signal COM1.80 VL3 INPower source voltage input t

Seite 19

24R-320HKR-320HQR-320HW1. Precautions for Handling Electronic ComponentsThis unit uses CMOS LSI in the integral part of thecircuits. When handling the

Seite 20

25R-320HKR-320HQR-320HWTo remove the outer case, proceed as follows.1. Disconnect the power supply cord.2. Open the oven door and block it open.3. Rem

Seite 21 - Ω ± 5% 1/4W

26R-320HKR-320HQR-320HWRemoval1. Disconnect the power supply cord and then removeouter case.2. Open the door and block it open.3. Discharge high volta

Seite 22 - TOUCH CONTROL PANEL ASSEMBLY

27R-320HKR-320HQR-320HW1. Disconnect the power supply cord, and then removeouter case.2. Open the door and block it open.3. Discharge high voltage cap

Seite 23 - During cooking

1R-320HKR-320HQR-320HWWARNING TO SERVICE PERSONNELMicrowave ovens contain circuitry capable of pro-ducing very high voltage and current, contact withf

Seite 24

28R-320HKR-320HQR-320HWSide ViewRear View1. Disconnect the power supply cord.2. Remove turntable and turntable support from ovencavity.3. Lay the oven

Seite 25 - Thermistors

29R-320HKR-320HQR-320HWhook, pushing and pulling upper portion of door towardthe oven face. Then check lower portion of the latchhook, pushing and pul

Seite 26 - TOUCH CONTROL PANEL SERVICING

30R-320HKR-320HQR-320HWSealer filmBacking filmAdhesive tape14.Now, latch head and latch spring are free.15.Remove door screen from door frame.16.Now,

Seite 27 - WARNING FOR WIRING

31R-320HKR-320HQR-320HW645123645123ABCDEFGHABCDEFGHFigure S-1. Pictorial DiagramHIGH VOLTAGECAPACITORH.V. RECTIFIERPOWER SUPPLY CORD 120V 60HzHIGH VOL

Seite 28 - POWER TRANSFORMER REMOVAL

32R-320HKR-320HQR-320HWFigure S-2. Control Unit Circuit645123645123ABCDEFGHABCDEFGHLSI UNITOVEN LAMPTURNTABLE MOTORFAN MOTORPOWERTRANSFOMERIF NOT SPEC

Seite 29 - POSITIVE LOCK

33R-320HKR-320HQR-320HW645123645123ABCDEFGHABCDEFGHFigure S-3. Printed Wiring Board of Power UnitRY1RY2E C BE C BE C BVRS1L1D7D3PSD4C2D1C1D2R8R7

Seite 30 - TURNTABLE MOTOR REMOVAL

34R-320HKR-320HQR-320HW∆∆∆*******∆*∆*∆∆PARTS LISTNote: The parts marked “∆” may cause undue microwave exposure.The parts marked “*” are used in voltag

Seite 31 - DOOR REPLACEMENT

35R-320HKR-320HQR-320HWHOW TO ORDER REPLACEMENT PARTSTo have your order filled promptly and correctly, please furnish the following information.1. MOD

Seite 32 - Adhesive tape

36R-320HKR-320HQR-320HW645123645123ABCDEFGHABCDEFGHOVEN AND CABINET PARTSAA7-107-14-14-54-44-136-57-34-37-84-92-11-71-127-67-31-101-94-107-107-107-84-

Seite 33 - HIGH VOLTAGE COMPONENTS

37R-320HKR-320HQR-320HW645123645123ABCDEFGHABCDEFGHDOOR PARTSCONTROL PANEL PARTSMISCELLANEOUS3-23-13-63-53-43-3Actual wire harness may be different f

Seite 34 - LIQUID CRYSTAL DISPLAY

2R-320HKR-320HQR-320HWMICROWAVE MEASUREMENT PROCEDUREA. Requirements:1) Microwave leakage limit (Power density limit): The power density of microwave

Seite 35

38R-320HKR-320HQR-320HWPACKING AND ACCESSORIESCOPYRIGHT © 2003 BY SHARP CORPORATIONALL RIGHTS RESERVED.No part of this publication may be reproduced,s

Seite 36 - PARTS LIST

3R-320HKR-320HQR-320HWSHARP ELECTRONICS CORPORATIONSHARP PLAZA, MAHWAH,NEW JERSEY 07430-2135SERVICE MANUALMICROWAVE OVENR-320HK/ R-320HQ/ R-320HWFOREW

Seite 37 - SCREWS,NUTS AND WASHERS

4R-320HKR-320HQR-320HWITEM DESCRIPTIONPower Requirements 120 Volts / 14.2 Amperes60 HertzSingle phase, 3 wire groundedPower Output 1200 watts (IEC TES

Seite 38 - OVEN AND CABINET PARTS

5R-320HKR-320HQR-320HWcontact a qualified electrician and have it replaced with a properlygrounded three-pronged wall receptacle or have a grounding a

Seite 39 - CONTROL PANEL PARTS

6R-320HKR-320HQR-320HWOPERATIONDESCRIPTION OF OPERATING SEQUENCEThe following is a description of component functions duringoven operation.OFF CONDITI

Seite 40 - Not replaceable items

7R-320HKR-320HQR-320HWsupplementary cooking is started. The time of supplemen-tary cooking is determined by experiment with each foodcategory and inpu

Kommentare zu diesen Handbüchern