Trouble shooting procedure of POWER SUPPLY
4-1.
Tools required
The following tools
are
required for
servicing.
4.
5V
11.3A and 12V 11.3A loads
1. Oscilloscope
5.
AC ammeter and
voltmeter
2.
Voltage regulator (Slidac)
3. Voltmeter (digital voltmeter)
4-2.
When R 1
is
open
Since this failure may possibly be due
to
short circuit
of
ac
line capacitor, RC1, C4, or Q1,
the
cause
has
to
be checked
in
accordance with the flowchart below. -
Flowchart
Phenomenon
and
others
Replacing
component
Gl
Set
the
oscilloscope
to
the
follow·
(
Start
ing
range.
Voltage range: 50V/div
~
Time range:
10us/div
Replace
R 1 with the new
one.
®
Shut off
the
AC
supply immedi-
Replace
the
following components
l
Gl
ately, when
the
ammeter coupled with new ones
in
this case, because
Connect the oscilloscope
to
the
AC
line increases abruptly. there may be possible destruction
in
probes
between
the
emit~
these components.
ter and collector
of
Q1.
01,
RC1.C4.Cl,C16
~
®
@
Should
01
be found
in
failure,
there will
be
need
of
replacing
Gradually increase the
the
following components, as
they
AC
voltage using *Slidac.
may possibly be
in
destruction,
too.
~
@
02,03,Dl,D3,Rl1,RS
Replace
the
defective
@
component with
the
new
Put
the
load into connection
in
NOTE:
Should 01
be found
in
fail~
this case and ensure
that
the
ure, there may be possible destruction
one.
following waveform appears.
in
RS,
too.
When
Step
(2)
is
carried
~
@
out
with
RS
in
open state,
it
causes
Gradually
increase the
r-
to
add
dc
voltage between
the
collec-
AC
voltage using *Slidac
h
tor
and
the
emitter
of
01 so
that
DC
and
ensure appearance
of
voltage may not decrease even after
the waveform shown
in
the
ac supply
was
shut
off.
So,
care
FIG·2.
320V
must be exercised
in
this
case
to
~
avoid continuous impression
of
the
DC
Check
proper output
of
voltage.
+5V and
+12V, respec-
tively.
-~
-
J,
1--35"S-
(
End
)
(Fig.
2)
* Slidac = Variable Voltage transformer