AN-Z7T
6. Removing the connecting terminals/3-dimensional Y/C separation PWB unit
assembly
6-1. Remove the two lock screws (yellow) and the two supports from the connecting terminals/3-dimensional Y/
C separation PWB unit assembly. Slide the PWB unit and draw the terminals out of the bottom plate.
6-2. Disconnect the connector (EA) from the connecting terminals PWB unit.
7. Removing the center duct and the PBS fan
7-1. Remove the one lock screw (yellow) from the center duct and detach the center duct.
7-2. Remove the one lock screw (yellow) from the PBS fan and detach the angle and the PBS fan.
Connecting terminals/
3-dimensional
Y/C separation PWB
unit assembly
6-1
7-1
6-2
7-2
Center duct
(EA)
PBS fan
Angle