9.0 Appendix A - IQ-400 Specifications
9.1 IQ-400 Features
2 Auxiliary Powered Outputs (cc# 89, 90)
1 Unsupervised Tamper Sense Input (S13)
4 Reader Ports:
-5-wire Wiegand interface
-4-wire PCSC Proprietary
4 Form C Door Strike Outputs
(2 Amps @ 24 VDC)
(cc# 1, 2, 3 and 4) 2 Amps continuous power @12/24 VDC
4 Door Left Open Outputs (or 4 External Shunt Options) (cc# 13, 14, 15 and 16)
4 Supervised Door Senses (S17, 19, 21, 23)
5 User Defined Sense Inputs (S14, S120, S121, S122, S123)
4 Request to Exit Inputs (S16, 18, 20, 21)
Battery Backed Clock Calendar
Flash RAM 128K standard (up to 256K)
Battery Backed RAM 256K standard (up to 512K)
LEDs for:
Power, alarm, on-line diagnostics
Reader Data [Error code, door status]
Tamper detect (S13)
Type of Communications: RS-232, RS-485, LAN
9.1.1 System Capacities
Cardholder Capacity: 8,000 (20,000 w/Memory Expansion)
Time Periods: 32
Holiday Time Periods: 32
Holiday List: 366 Days (Leap Year)
History Transactions: 4,000 regardless of memory size
9.1.2 Electrical Ratings
Power: 12VDC
Draw: 524mA @ 13.65V
Relay Contacts 2 A @ 24 VDC
Data0/Data1 5 Vdc @ 0 mA for Logic 1
0 Vdc @ 5mA for Logic 0
Card Reader Draw: 100mA @ 12 VDC
Alarm Point Voltage 5.0 Vdc @ 0.0 mA when Sense Input is in Open Circuit Physical State.
& Tamper Voltage 0.0 Vdc @ 5.0 mA when Sense Input is in Short Circuit Physical State.
1.6 Vdc @ 3.4 mA when Sense Input is in Alarm Physical State.
0.9 Vdc @ 4.1 mA when Sense Input is in Normal Physical State.