~ In this state, enter the command, listed below, and "ENTER" on the keyboard for adjustment.
Press "ENTER" and make sure that "OK" appears on the terminal software.
If "ERR" appears, try again.
RS232C commands list
Command
MSET1001
MOFR~~~~
MOFG~~~~
MOFB~~~~
MGAR~~~~
MGAG~~~~
MGAB~~~~
MINF0000
MINF0001
MINF0002
Function
Background adjustment started.
R OFFSET value adjusted.
G OFFSET value adjusted.
B OFFSET value adjusted.
R GAMMA value adjusted.
G GAMMA value adjusted.
B GAMMA value adjusted.
R GAMMA table displayed.
G GAMMA table displayed.
B GAMMA table displayed.
Remarks
Adjustment ended at a value other than 1001.
Range: 0000~0256
Range: 0000~0256
Range: 0000~0256
Range: 0020~0180
Range: 0020~0180
Range: 0020~0180