XE-A41S PROGRAM MODE
2 – 9
[JOB#6] PRINT FORMAT -- ABCDEFGH --
MRS = 00000011
[JOB#7] RECEIPT PRINT FORMAT -- ABCDEFGH --
MRS = 00000000
[JOB#10] POWER SAVING -- YXXX --
MRS = 0030
[JOB#11] LOGO PRINTING -- A --
MRS = 1
[JOB#15] FUNCTION SELECT2 -- ABCDEFGH --
MRS = 000000000
[JOB#16] UPC/EAN FUNCTION -- ABCDEFGH --
MRS = 00000000
A, B: Not used (Fixed at “00”)
C: TIME PRINTING (for all receipt) C
PRINT 0 ★
NOT PRINT 1
D: DATE PRINTING (for all receipt) D
PRINT 0 ★
NOT PRINT 1
E: CONSECUTIVE NO. PRINTING E
PRINT 0 ★
NOT PRINT 1
F: Not used (Fixed at “0”)
G: ZERO SKIP IN PLU/UPC REPORT G
NOT SKIP 0
SKIP 1 ★
H: ZERO SKIP IN GENERAL,CLERK,HOURLY,
DAILY REPORT
H
NOT SKIP 0
SKIP 1 ★
A, B: Not used (Fixed at “00”)
C: SUBTOTAL PRINT [AT] [ST] KEY C
NOT PRINT 0 ★
PRINT 1
D: MDSE SBTL PRINT AT [MDSE ST] KEY D
NOT PRINT 0 ★
PRINT 1
E, F, G: Not used (Fixed at “000”)
H: PURCHASE NO. PRINTING H
PRINT 0 ★
NOT PRINT 1
Y: POWER SAVING function when a time is displayed Y
Yes (Enable) 0 ★
No (Disable) 1
XXX: POWER SAVING TIME to POWER OFF
= 001 to 254 (minutes)
or 999 (Inhibit)
A: LOGO MESSAGE CONTROL A
3-LINE HEADER INSTEAD OF GRAPHIC LOGO 0
GRAPHIC LOGO ONLY 1 ★
GRAPHIC LOGO AND 3-LINE FOOTER 2
6-LINE HEADER 3
GRAPHIC LOGO AND 3-LINE HEADER 4
3-LINE HEADER AND 3-LINE FOOTER 5
A, B, C, D, E, F: Not used (Fixed at “000000”)
G: TAX DELETE in REG mode G
ENABLE 0 ★
DISABLE 1
H: MANUAL TAX in REG mode H
ENABLE 0 ★
DISABLE 1
A, B: Not used (Fixed at “00”)
C: DEPT/PLU/UPC (EAN) code printing on journal C
NO 0 ★
YES 1
D: DEPT/PLU/UPC (EAN) code printing on receipt D
NO 0 ★
YES 1
E: LERNING FUNCTION of UPC (EAN) ENTRY E
YES 0 ★
NO 1
F: PRICE ENTRY after ISBN or ISSN F
COMPULSORY 0 ★
INHIBITTED 1
G: PLU/UPC (EAN) PRICE LOOK UP AT
REFUND ENTRY
G
YES 0 ★
NO 1
H: C/D check of UPC (EAN) H
NO 0 ★
YES 1
Kommentare zu diesen Handbüchern