LD-22113-7
7) Timing Characteristics of input signals
Timing diagrams of input signal are shown in Fig.3-A, Fig.3-B.
7-1) Timing characteristics
Table 7-1
Parameter Symbol MIN TYP MAX Unit Remarks
Clock frequency 1/Tc 4.5 6.3 6.8 MHz
High time Tch 50
− −
ns
Low time Tcl 50
− −
ns
Data Setup time Tds 50
− −
ns
Hold time Tdh 50
− −
ns
Hsync-Clock phase difference THc 50
−
120 ns
Hsync-Vsync phase difference TVh 0
−
TH-10 µs
Note) In case of lower frequency, the deterioration of display quality, flicker etc., may be
occurred.
7-2) Horizontal display position
①In case ENAB is active
The horizontal display position is determined by ENAB signal and the input data
corresponding to the rising edge of ENAB signal is displayed at the left end of the active area.
(shown in Fig.3-A.)
Parameter symbol Min. Typ. Max. Unit Remark
Horizontal 50 63.5 80 µs
sync. signal
Cycle TH
THe+308 400 440 clock
Pulse width THp 4 12 30 clock
Enable signal Setup time Tes 50
− Tc−10
ns
Pulse width Tep 320 clock
Hsync-Enable signal phase
difference
THe 14
−
72 clock
Horizontal display period THd 320 320 320 clock
②In Case ENAB is “Low” . (shown in Fig.3-B)
Parameter symbol Min. Typ. Max. Unit Remark
Horizontal 56 63.5 80 µs
sync. signal
Cycle TH
380 400 440 clock
Pulse width THp 4 12 30 clock
Hsync-data signal phase
difference
THe 72 72 72 clock
Horizontal display period THd 320 320 320 clock
7-3) Vertical Display Position
Parameter Symbol Min. Typ. Max. Unit Remarks
Vertical sync. Cycle TV 246 263 330 line
signal
Pulse width TVp 1
− −
line
Vertical display start position TVs 6 6 6 line
Vertical display period TVd 240 240 240 line
ENAB signal has no relation to the vertical display position.
Kommentare zu diesen Handbüchern