LD-22113-18
Reliability Test Conditions for TFT-LCD Module
Table 14
Remark) Temperature condition is based on operating temperature conditions on (5)-Table 5-1.
No. Test items Test Conditions
1
High temperature storage test
Ta= +95℃
240h
2
Low temperature storage test
Ta= −40℃
240h
3
High temperature and
high humidity operating test
Tp= +60℃ , 95%RH
240h
4
High temperature operating test
Tp= +85℃
240h
5
Low temperature operating test
Ta= −30℃
240h
6
Electro static discharge test
±200V・200pF(0Ω) 1 time for each terminals
7
Shock test
980m/s
2
・6ms, ±X;±Y;±Z
3 times for each direction
(JIS C0041, A-7 Condition C)
8
Vibration test
Frequency range:8∼33.3Hz
Stroke:1.3mm
Sweep:33.3Hz∼400Hz
Acceleration:28.4m/s
2
Cycle:15 minutes
X,Z 2 hours for each directions, 4 hours for Y direction
(total 8 hours) 【caution】(JIS D1601)
9
Heat shock test
Ta= −40℃∼+95℃ / 200 cycles
(0.5h) (0.5h)
【Note】Ta= Ambient temperature, Tp= Panel temperature
【Check items】In the standard condition, there shall be no practical problems that may affect
the display function.
【caution】X,Y,Z directions are shown as follows:
X
Y
Z
Kommentare zu diesen Handbüchern