66 YP4-6-825A3P Table of Contents Index Great Plains Manufacturing, Inc.
401-652M Table of Contents Index 2015-01-26
Magnehelic
®
Gauge Troubleshooting
If the Magnehelic
®
gauge does not read zero with the fan
off, inspect the gauge, and re-zero as needed.
Check for chamber and breather line problems before
re-zero. Re-zero cannot accurately compensate for leaks
and blockages.
Re-zero the Magnehelic
®
gauge on level ground with the
fan off, and if possible, under no-wind conditions. Turn
the set screw on the meter face until it reads zero from
the tractor driver’s viewing position.
Problem Cause Solution
Non-zero
with fan off
Zero drift Re-zero per
instructions below
Gauge
reading
lower than
sensor
Relief port plug
missing/damaged
Replace plug
Breather line
blocked or kinked
Clear breather line
Leak in sensing
line
Check line to
chamber
Gauge damaged Check for loose
cover, damaged
O-ring
1
Figure 78
Magnehelic
®
Gauge
29842
Port ID for Troubleshooting:
Over-pressure relief port (with plug in place)
Low-pressure port (breather/atmospheric pressure)
High-pressure port (from manifold chamber)
Alternate high/low ports are plugged.
Winter testing/maintenance advisory:
Gauge readings may be inaccurate or sluggish below
20°F
2
3
4
3
2
4
1
Seitenansicht 69