Introduction
Connections
Setup
Using the Software
Appendix
MODEL AN-LS1
OPERATION MANUAL
Ethernet to RS-232C Network Converter
Please read this operation manual carefully
to ensure correct use of the Ethernet to RS-
232C Network Converter.
Please read this operation manual together
with the “IMPORTANT INFORMATION”
leaflet.
Prior to installation of this product, carry
out the appropriate network settings.
Seitenansicht 0
1 2 3 4 5 6 ... 53 54

Inhaltsverzeichnis

Seite 1 - OPERATION MANUAL

IntroductionConnectionsSetupUsing the SoftwareAppendixMODEL AN-LS1OPERATION MANUALEthernet to RS-232C Network Converter• Please read this operation ma

Seite 2 - Accessories

10Connecting the AC AdaptorTake the following steps to connect AN-LS1’s AC adaptor.1 Plug the AC adaptor’s DC plug into AN-LS1’s DC IN jack.2 Plug the

Seite 3 - Contents

11SetupEntering SETUP MENUConnect AN-LS1 to a computer using RS-232C or Telnet, and open the “SETUP MENU” on the computerto carry out various settings

Seite 4 - Part Names and Functions

12When Connecting Using Telnet1 Click “Start” from the Windows desktop and select “Run”.2 Enter “telnet 192.168.150.2” in the text box that opens up.(

Seite 5 - LED Indicators

13SetupSETUP MENU DescriptionSETUP MENU (Main Menu)S E T U P M E N U[1]IP Address [2]Subnet Mask [3]Default Gateway[4]User Name [5]Password[6]RS-23

Seite 6 - Wall Mount

14ADVANCED SETUP MENU******************** ADVANCED SETUP MENU ***********************[1]Auto Logout Time [2]COM Redirect Port [3]Busy Reply[4]Input

Seite 7 - Overview

15SetupBasic ProcedureEnter number or symbol of item to be selected on the “SETUP MENU”. When setting, input the detailsto be set. Setting is carried

Seite 8 - Connecting to an Ethernet LAN

16Set Items(e.g.) When setting IP Address (change from 192.168.150.2 to 192.168.150.3)▼ The SETUP MENU———————— S E T U P M E N U ——————————[1]IP Ad

Seite 9 - Connecting Devices

17SetupQuitSave settings and quit. ([S]Save & Quit)Save set values and quit menu.▼ The SETUP MENU———————— S E T U P M E N U ——————————[1]IP Add

Seite 10 - Connecting the AC Adaptor

18Setting of Each ItemThe setting procedure for each item will be explained. For the basic procedure, please refer to page15.IP Address Setting ([1]IP

Seite 11 - When Connecting Using RS-232C

19SetupUser Name Setting ([4]User Name)Carrying out security protection using user name.setup>4User Name :Please Enter : an-ls1(change) —>

Seite 12 - When Connecting Using Telnet

2Outstanding FeaturesAN-LS1 is a network converter for converting TCP/IP protocol on Ethernet to serial (RS-232C). AN-LS1 enables Sharp projectors wi

Seite 13 - SETUP MENU Description

20Unit Name Setting ([7]Unit Name)It is possible to assign a unit name.When searching using Sharp COM Redirection Software, it is possible to verify a

Seite 14 - ADVANCED SETUP MENU

21SetupThe followings are descriptions of the ADVANCED SETUP MENU.Setting Automatic Logout Time (ADVANCED[1]Auto Logout Time)If there is no input afte

Seite 15 - Basic Procedure

22Busy Reply Setting (ADVANCED[3]Busy Reply)The input terminals of AN-LS1 can be RS-232C (CONTROLLER) and 10BASE-T. Respective inputterminals can be c

Seite 16 - Set Items

23SetupCarrying out Network Ping Test (ADVANCED[5]Network Ping Test)It is possible to confirm that a network connection between AN-LS1 and a computer

Seite 17

24Setting of Port for Search (ADVANCED[0]Port for Search)Sets the port number used when Sharp COM Redirection Software searches for AN-LS1.advanced>

Seite 18 - Setting of Each Item

25Using the SoftwareAbout Sharp COM Redirection SoftwareUsing Sharp COM Redirection Software, it is possible to create a “Virtual COM” port. If genera

Seite 19

26InstallationThe Sharp COM Redirection software (Virtual COM Driver software) is installed using the installationprogram provided on the CD-ROM.This

Seite 20

27Using the Software• Please change the destination only when necessary. (In general, it is not necessary to changethe destination folder.)• If “Cance

Seite 21

286 Enter a check mark against Virtual COMs to be added to the computer and click“OK”.• It is necessary to add the same number of Virtual COMs as the

Seite 22

29Using the SoftwareStartingLaunch Sharp COM Redirection Software.1 Launch by double clicking the Sharp COM Redirection Software icon in the ControlPa

Seite 23

3IntroductionContentsIntroductionOutstanding Features ...

Seite 24

30Explanation of the Screen▼ Configuration dialog89214 5 6731 List display areaList display of states of all units recognizing Sharp COM Redirection S

Seite 25

31Using the SoftwareOperationsSearch and AddSearches for units on a network and adds to the list display.1 Click “Search”.| “Search tool” dialog is di

Seite 26

322 Click the unit to be added to list display.3 Click “Add to List”.| Added to list display after carrying out communication to each selected unit.

Seite 27

33Using the SoftwareSelecting Virtual COM PortSelecting Virtual COM port used when communicating with AN-LS1.1 Click the “Virtual COM” column.| The “V

Seite 28

342 Click and select the “Virtual COM” number to be used for communication with AN-LS1.3 Click on an area outside the “Virtual COM” pull down menu.| “

Seite 29 - Starting

35Using the SoftwareAdd (Manual)Adding units to the list display manually in cases such as when units cannot be found, even by searching.1 Click “Add”

Seite 30 - Explanation of the Screen

362 Enter IP address and click “OK”.| Unit will be added.

Seite 31 - 1 Click “Search”

37Using the SoftwareRefreshChanging the list display content to the latest state.1 Click “Refresh”.| Model Name, Unit Name and Status will be updated

Seite 32 - 3 Click “Add to List”

38DeleteDeleting an unit from the list display.1 Click on the unit to be deleted.2 Click “Delete”.

Seite 33 - Selecting Virtual COM Port

39Using the Software| A confirmation dialog will be displayed.• If you do not want to delete the unit, click “Cancel”.3 Click “Yes”.| The unit to be d

Seite 34

4Part Names and FunctionsMain BodyTX/RX LED indicator (Page 5)Lit when transmitting data.10BASE-T Ethernet terminal (Page 8)To connect to an Ethernet

Seite 35 - 1 Click “Add”

40PasswordIf units with user name/password set appear within the list display, the user name/password for thoseunits must be entered.Enter when commun

Seite 36 -

41Using the Software2 Click “Password”.| A dialog prompting entry of user name/password will be displayed.3 Enter the user name and password being set

Seite 37 - 1 Click “Refresh”

42SettingSetting of computer data communication port number and search port number.1 Click “Setting”.| “Setting” dialog will be displayed.2 Enter “Sea

Seite 38 - 2 Click “Delete”

43Using the SoftwareOK/CancelWhen defining content of setting or change, click “OK” when closing the “Configuration dialog”.When canceling content of

Seite 39 - 3 Click “Yes”

44Changing / Removing the SoftwareBe sure to always uninstall the Sharp COM Redirection Software, when reinstalling the Sharp COMRedirection Software

Seite 40 - 1 Click the subject unit

45Using the Software5 Select “Modify”, “Repair” or “Remove”, and then click “Next>” on the “Welcome”dialog box. “Modify”For adding or removing Virt

Seite 41 - 2 Click “Password”

46Connecting Pin AssignmentsRS-232C Terminal: 9-pin D-sub male connectorPin No. Signal Name I/O Reference1 CD Not connected2 RD Receive Data Input Con

Seite 42 - 1 Click “Setting”

47AppendixTroubleshootingThe POWER indicator on the top panel does not light green.\ Check if the power plug of the AC adaptor is disconnected from th

Seite 43 - OK/Cancel

48Check the network settings for the computer and AN-LS1.\ Check the following network settings for AN-LS1.• IP address\\ Check that the IP address fo

Seite 44

49AppendixC:\>ipconfig “RETURN”Usage examples of ipconfigC:\>ipconfig /? displays how to use “ipconfig.exe”.C:\>ipconfig displays the set IP

Seite 45 - Using the Software

5IntroductionLED IndicatorsThe LED indicators at the side and on the top of AN-LS1 represent the contents in the followingtable.POWERLINKTX/RXName LED

Seite 46 - Connecting Pin Assignments

50\ Check if the “TCP/IP” protocol is operating correctly using the “PING” command. Also, check if anIP address is set.1. Open a command prompt (MS-DO

Seite 47 - Troubleshooting

51AppendixSharp COM Redirection Software does not operate.AN-LS1 cannot be found by a search.\ Check the connection. (Refer to “When connecting AN-LS1

Seite 48

52SpecificationsMain BodyDescription Ethernet to RS-232C Network ConverterInput voltage DC 6.3 V, 400 mAOperating temperature 41°F to 104°F (5°C to 40

Seite 49

53AppendixIndex10BASE-T Ethernet terminal ... 8AAccept All IP Addr... 23Accept IP A

Seite 50

SHARP CORPORATION

Seite 51 - Initialize (INIT.) button

6Wall MountYou will find it convenient to mount AN-LS1 on the wall, using two screws, as indicated below.1 Screw two screws (not included) into the wa

Seite 52 - Specifications

7ConnectionsOverviewUse the following procedure for connection of AN-LS1.1 Connect AN-LS1 to an Ethernet LAN. (Page 8)2 Connect devices to AN-LS1. (Pa

Seite 53 - Appendix

8Connecting to an Ethernet LANConnect AN-LS1 to a hub or a computer using a Category 5 cable.• It is necessary to perform computer setting according t

Seite 54 - SHARP CORPORATION

9ConnectionsConnecting DevicesConnect a commercially available controller or computer and a projector to AN-LS1.Connecting a Controller or a ComputerI

Kommentare zu diesen Handbüchern