6
XG-C40XU
(
1
)
XG-C40XE
(
1
)
No. Adjusting point Adjusting conditions Adjusting procedure
13 Horizontal
center
1. Feed the NTSC monoscope
pattern signal.
2. Group : VIDEO 2
Subject : N358-DLY (4)
N443-DLY (0)
PAL-DLY (3)
SECAM-DLY (0)
Make sure the settings are
as above.
3. Group : VIDEO 1
Subject : NTSC-H
» Using the control switches or the remote controller
buttons, adjust the data to have the same overscan
in Reft and Right.
2.0Vp-p
14 Video picture
adjustment
1. Feed the split colour bar sig-
nal.
Group : VIDEO 1
Subject : PICTURE
2. Connect the oscilloscope
between pin (2) of P801 and
GND.
» Using the control switches or the remote controller
buttons, adjust the black-to-white (100%) level
difference to 2.0 ±0.06 Vp-p.
17 Tint 1. Feed the split colour bar
signal.
Group : VIDEO 1
Subject : TINT
2. Connect the oscilloscope to
pin (4) of P801.
» Using the control switches or the remote controller
buttons, adjust the data to have the -(B-Y) wave-
form downhill straight.
» After adjusting, adjust the
value of TINT up 3 point.
16 Video AGC 1.
Feed the split colour bar signal.
Group : VIDEO 1
Subject : AGC
» Using the control switches or the remote controller
buttons, adjust the setting until the white signal
becomes bit-less.
15 Video
brightness
adjustment
1. Feed the baseband (split
colour bar) signal. (The ON-
AIR signal is not accepted
because of its too much
noise.)
Group : VIDEO 2
Subject :
VROS/VGOS/VBOS
2. Press the control switch or
the remote control’s mute
button (to set the gamma
correction to the process
setting).
» Using the control switches or the remote controller
buttons, adjust the setting until the black signal
becomes bit-less.
18 NTSC colour
saturation level
1. Feed the split colour bar sig-
nal.
Group : VIDEO 1
Subject : N-COLOR
2. Connect the oscilloscope to
pin (1) of P801.
» Using the control switches or the remote controller
buttons, adjust the difference between the 100%
white portion and the red portion to 0.00 ±0.05 Vp-p.
(same as 100% white)