10.0 Routine Maintenance/Adjustments
51
3. Place the suction line of the transfer pump into the breather cap hole. Place the pressure line
of the transfer pump into an empty five-gallon pail.
4. Turn on the transfer pump and fill the pail. Repeat until tank is empty.
5. Replace the oil filter. Place a thin film of new hydraulic oil on the seal of the new filter to
insure a proper seal. Firmly hand-tighten the filter onto the filter head.
6. Fill the tank with recommended fluid until the level is 3/4” below the top of the inside of the
tank.
NOTE: DO NOT OVERFILL. Overfilling may cause leakage when the hydraulic fluid is hot.
7. Reinstall the breather cap.
8. Before turning on the machine, make sure all hydraulic hose fittings are tight. Make sure the
oil filter has been firmly hand tightened to the filter head.
9. Unlock and turn on the main power to the machine. Turn on the hydraulic motor by pressing
both cut buttons once. Inspect the hydraulic system for leaks. If leaks are found, turn off
main power to the machine and tighten any leaking fittings.
10. Repeat step 9 as necessary.
10.5 Line Light Adjustment
The line light comes on whenever main power is turned to the ON position. The light from each of two
bulbs reaches the table after passing between the knife and clamp, (Figure 22).
Figure 22
Each light is focused with an adjusting screw mounted on the line light bracket, behind the console.
1. Tilt the console down by removing the two screws at the top.
2. Place a wide sheet of paper on the cut stick to view the line.