9.6 OUT PCB Features (P/N: 03-10032-201F)
16 Form C Relay Dry Contact Outputs (2.0 amps @ 12/24 VDC continuous power)
16 Unsupervised Sense Inputs (Alarm points 56-71)
LEDs for: status, +5Vdc, +12VDC
Supervised Tamper detect (S13)
9.6.1 System Capacities
Enclosure Dimensions: 18”H x 11.5”W x 6”D (45.7cm x 29.2cm x 15.2cm)
Weight: 38 lbs. (17.3kg)
Temperature: 32°F to 115°F (0°C to 46°C)
Communications: 50-pin Ribbon Cable
9.6.2 Electrical Ratings
Sense Inputs Open Switch 0.0 mA @ 12 VDC
Closed Switch 1.3 mA @ 0.0 VDC
Power: 12VDC
Draw: 974mA @12V
Relay Contacts 2 A @ 24 VDC
9.6.3 Spare Parts- OUT PCB
Part Number Description Designation
83-02083 2-pin Plug Connector P13 (Pins 5-6)
83-02084 4-pin Plug Connector P1- P12 (two connectors per plug), P13 (Pins 1-4)
79-03022 DPST Relay K1- K16
83-2007 Jump Connector P14
Page xcviii of 110 IQ-400 Installation Manual 33-10057-001-C