Operation
The controls are designed so that each mode of
operation is independent of the other. All electricity
could be cut off and the refrigerator still operate in
the GAS mode. 12 Volts is not necessary to operate
the control circuit.
Gas Mode
The GAS mode uses a thermocouple system to
produce a self-generating power (milli-volts). The
Thermocouple, when heated by the burner flame,
produces enough milli-volts to hold the safety valve
open. A loss of flame de-energizes the safety valve
and shuts the propane gas down.
An Interrupter device is coupled in series with the
thermocouple so that the milli-amps cannot flow to
the Safety Valve (part of the Control Valve) until the
Interrupter contacts are shunted (jumpered). The
shunt is provided by the Selector switch when it is
switched to GAS mode.
The Selector switch not only serves as a mode se-
lector but also as an interlock between modes so
that two sources of power cannot be energized si-
multaneously.
The GAS mode utilizes an adjustable GAS con-
trol. The control can be manually adjusted to me-
ter the fixed amount of propane gas to the burner
thereby acting as a temperature control to main-
tain cabinet temperature.
Important: Unlike an automatic gas control, this con-
trol does not cycle the flame from high
fire to low fire as with other types of RV
refrigerators. If the cooling load changes,
the GAS control must be manually ad-
justed to maintain the same temperature.
The gas ignition method uses a piezo spark ignitor
- requiring a manual ignition of the burner. See the
Lighting Instructions.
Electric Modes
The AC mode, and DC mode in the case of the 3-
Way model, is thermostatically controlled by a non-
adjustable thermostat. The Thermostat has a capil-
lary sensor attached to the cooling fin. The electric
heater (AC or DC) will cycle in response to the fin
temperature to maintain the cabinet temperature.