Lighting and Start-Up Instructions
DO NOT HOLD GAS VALVE (D) IN MORE THAN 30 SECONDS, IF FLAME IS NOT INDICATED WITHIN THIS
TIME, TURN GAS TO OFF, WAIT 2 MINUTES AND RETRY. CONTINUING TO HOLD GAS VALVE IN WILL
CAUSE GAS BUILD-UP IN THE BURNER AREA AND CAN RESULT IN AN EXPLOSION WHICH CAN CAUSE
PERSONAL INJURY OR DEATH.
Lighting Instructions - Gas Operation
1. Open the lower vent door on the outside rear of
the vehicle to gain access to the rear of the re-
frigerator. Open window on front side of Burner
Box to view the burner shown in Figure 8.
2. Set the Energy Selector Switch (A) to the GAS
position.
3. Set the Gas Control Selector (D) to the HIGH
COOL position.
4. Ensure that the manual shut-off valve is open.
See location in Figure 1.
5. While pushing the Gas Control Selector switch
(D) in, press the spark ignitor push-button (B) in,
several times in rapid succession (A click should
be heard each time it is depressed.). The burner
should light; however, continue to hold the Gas
Control Selector (D) in for another 15 seconds
before releasing.
6. Verify that the flame remains lit by looking at the
burner through the burner box window in Figure 8.
7. Adjust the Gas Control Selector (D) to the de-
sired cooling setting. Close viewing window on
Burner Box.
Start-Up Instructions - AC Electric
Operation
1. Verify that 120 volts AC is available to the refrig-
erator and that the AC fuse (C) in the control
bracket is operational.
2. Set the Energy Selector Switch (A) to the AC
position and verify that the Gas Control Selector
(D) is in the OFF position.
3. No other action is required since a non-adjust-
able thermostat is provided to prevent food from
freezing in the electric modes.
Start-Up Instructions - DC Electric
Operation (3-Way)
1. Verify that 12 volts DC is available to the refrig-
erator and that the in-line DC fuse in the DC
heater wire assembly is operational.
2. Set the Energy Selector Switch (A) to the DC
position and verify that the Gas Control Selector
(D) is in the OFF position.
3. No other action is required since a non-adjust-
able thermostat is provided to prevent food
freezing in the electric modes.
Shut-Down Instructions - All Models
1. Set the Gas Control (D) to OFF position.
2. Set the Energy Selector Switch (A) to GAS
position.
NOTE:
The Gas Control and Energy Selector must
be switched to the above positions to com-
pletely shut down the refrigerator.
*
323 models & 322
model with DC add-on
*
WARNING
Manual Shut-Off Valve
(shown in open position)
Figure 1