Sharp R-610D Handbuch Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 144
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
Safety
1-5
Part 1105120-01
E 2013 Nordson Corporation
First Aid
Seek immediate medical attention for skin burns and direct UV exposure to
the eyes.
Microwave Radiation
WARNING: The lamp system utilizes high powered RF microwave energy
generated by a magnetron to provide power to the UV lamp. This
technology is identical to that of residential microwave ovens and like these
ovens can be dangerous if misused. The lamp system is safe provided that
the RF screen and gasketing are intact. Any damage such as rips or holes
in the screen may cause leakage of dangerous amounts of microwave
radiation. The power to the lamp is interlocked to the RF detector and will
shut down if microwave leakage exceeds safe levels. Any excessive
leakage will cause the system to shutdown.
Currently there are two organizations that set recommended guidelines for
exposure to occupational microwave radiation exposure, OSHA (U.S.
Department of labor, Occupational Safety and Health Administration
Directive 29cfr 1910.97) and ANSI (American National Standards Institute
Directive C95.11982). The ANSI directive, which is more stringent and
most commonly referred to, states that individuals should not be exposed to
microwave radiation levels above 8 mW/cm
2
at 2.45 GHz on a continuous
basis, or an average of 8 mW/cm
2
over a six minute period.
RF levels near the CoolWave 2 system installation should be checked
periodically. To measure RF levels, a hand-held survey meter is available
from ETS-Lindgren company. Their HI-1501 Survey Meter is calibrated for
2450 Mhz microwave sources and can measure RF levels from 02, 010,
and 0100 mW/cm
2
More information can be obtained on the internet from
http://www.etslindgren.com/.
Radio Interference
UV lamps are classified as non-consumer industrial, scientific, and medical
(ISM) equipment, as defined in Federal Communications Commission
(FCC) Rules and Regulations Volume 47, Part 18. As required by these
rules, Nordson Corporation verifies that their systems are capable of
compliance with applicable technical standards governing radiated
emissions when the equipment is properly maintained and is installed in an
appropriate light shield. This system complies with EN55011 (CISPR-1,
Group 2, Class A).
NOTE: Nordson UV lamps operate at a fundamental frequency of 2.45
GHz. They may cause interference with wireless local area networks
(WLANs) that also operate at this frequency.
Ozone
Ozone (O
3
) is a colorless gas that is generated by the reaction of
short-wave UV light (around 200220 nanometers) with air, and it occurs
whenever high-energy electrical discharge is present.
Seitenansicht 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 143 144

Kommentare zu diesen Handbüchern