Installation
3-17
Part 1105120-01
E 2013 Nordson Corporation
The exhaust blower and duct size for each application will depend on many
variables. Size all blowers to accommodate all losses in the ductwork and
ensure that the specified air flow and pressure for each lamphead is
maintained.
AirShield Ventilation System
Figure 3-12 shows a standard AirShield Ventilation System kit installed on
an external blower lamphead. A high flow AirShield kit is also available.
Before mounting the lamphead on the AirShield enclosure, switch the
pressure hose from the top or front port to the bottom port as described in
Switching Pressure Ports on page 3-18.
Use eight M4 screws to mount the AirShield enclosure to the lamphead.
The internal blower lampheads are mounted to the kits in the same way.
Refer to the Parts section for the AirShield kit part numbers.
NOTE: Recommended Flexible Duct Hose for exhaust extraction:
McMaster-Carr part number 55125K26, neoprene coated 6-in ID hose. Use
worm clamps to connect the hose to the vent stubs.
8M4 x 35 Screws (Std Kit)
8M4 x 50 Screws (High Flow Kit)
(included in kits)
6-in. Exhaust
6-in. Intake
Quartz Plate
High Flow Kit
Standard Kit
48.1 mm
(1.894 in.)
38.1 mm
(1.5 in.)
25.4 mm
(1.0 in.)
35.4 mm
(1.394 in.)
Top Pressure Port
Port for Bottom Pressure Reading
Figure 3-12 AirShield Kit Installation (External Blower Lamphead Shown)