2.18 ABNORMAL CONDITION IN TONER DENSITY DETECTION
- Phenomenon -
The Auto ID indicator or the selected manual ID level blinks. (No SC Code is
indicated.)
- Definition -
If the Vsg goes below 2.5 volts or Vsp goes above 7.5 volts 5 times in a row.
- Possible Causes -
Incorrect Vsg voltage
Dirty ID sensor
Low toner density
ID sensor defect
Main board defect
- Action -
Check the Vsg voltage displayed in the magnification indicator by SP Mode
#55.
5.00 0.00 (Vsg 2.5 volts)
Is the copy image too light?
No Yes
Refer to Light Copy section.
Is the ID sensor circuit open?
No Yes
Replace the ID sensor and adjust the Vsg to 4.02 ± 0.2 volts.
Replace the main board and adjust the Vsg to 4.02 ± 0.2 volts.
Is the ID sensor surface dirty with toner?
No Yes
Clean the ID sensor with blower brush and/or damp cloth, then
check and/or adjust the Vsg to 4.0 ± 0.2 volts. If toner scattering
occur, correct it. (Refer to Toner Scattering section.)