Unit Description
32
Receiver Tank Sight Glass: The receiver tank sight glass
is used to assist in checking the amount of refrigerant in the
system.
Compressor Oil Sight Glass: The compressor oil sight
glass is used to check the relative level of compressor oil in the
compressor sump.
Unit Protection Devices
High Pressure Cutout Switch (HPCO): This normally
closed switch monitors the discharge pressure at the
compressor. It opens on high discharge pressure to shut the unit
down to prevent damage.
Suction Pressure Regulator (SPR): This component is a
mechanical control device used to limit the suction pressure to
the compressor. The valve controls suction pressure based on
the actual system pressure. (Scroll compressor units: The SPR
is not used if the unit is equipped with an ETV.)
Electronic Throttling Valve (ETV): (Scroll compressor
units only.) This component is an electromechanical control
device used to limit the suction pressure to the compressor. The
valve is controlled by the microprocessor controller.
Engine Oil Pressure Switch/Sensor: The engine oil
pressure switch/sensor is located on the filter head above the
bypass oil filter. Engine oil pressure should rise immediately
on starting. If engine oil pressure drops below 10 ± 2 psig (69 ±
14 kPa), the switch/sensor signals the microprocessor to stop
the engine.
Preheat Buzzer: The preheat buzzer sounds when the
CYCLE-SENTRY
TM
system energizes the glow plugs. This
should warn anyone near the unit that the CYCLE-SENTRY
TM
system is about to start the diesel engine.
Coolant Temperature Sensor: This sensor provides an
engine coolant temperature input to the microprocessor. If the
engine coolant temperature is too high, the controller stops the
unit and records an alarm.
Electric Motor Overload Relay (Model 50): The
overload relay protects the electric standby motor. The
overload relay opens the circuit from the contactor to the
electric motor if the motor overloads for any reason and an
alarm will occur. The relay resets when the alarm code is
cleared.
Fuses: Sizes and functions are described in the Specifications
section of this manual.