Unit Operation
66
Sending a ServiceWatch Data
Logger Start of Trip
When the unit is turned on, press and hold the ENTER Key for
5 seconds to send a Start of Trip (SOT) marker to the unit
ServiceWatch Data Logger and the optional DAS Data Logger
(if equipped).
Figure 40: ENTER Key
Pretrip Test
A Pretrip Test verifies unit operation. The PRETRIP Key
allows either a Full Pretrip Test or an Engine Running Pretrip
Test to be initiated by the operator.
Pretrip Test Conditions
The current unit settings are saved and restored at the end
of the Pretrip Test or if the unit is turned off and back on.
The Pretrip Test can be run in either Diesel or Electric
Mode.
The unit will auto switch from Diesel Mode to Electric
Mode or from Electric Mode to Diesel Mode during a
Pretrip Test if these features are enabled and the auto
switch conditions occur.
Conditions where Pretrip Tests are
not allowed
Pretrip Tests are not allowed if any shutdown alarms are
present.
Pretrip tests are allowed with some Check and Log alarms
present.
Pretrip Test Sequence
Pretrip tests proceed in the order shown below.