Specifications
83
Compressor Oil Type Ester base P/N 203-516 required for Scroll compressor
Discharge Pressure Regulator Valve Setting 350 ± 5 psig (2413 ± 34 kPa)
High Pressure Cutout Switch: Open
Close
470 ± 7 psig (3241 ± 48 kPa)
375 ± 38 psig (2586 ± 262 kPa)
* When the compressor is removed from the unit, oil level should be noted or the oil removed from the
compressor should be measured. This is to be sure that the same amount of oil can be added before placing the
replacement compressor in the unit.
Electrical Control System
Control System Voltage 12.5 Vdc
Battery Charging System 12 volt, 37 amp, brush type, Thermo King alternator
Voltage Regulator Setting 13.8 to 14.4 volts @ 77 F (25 C)
NOTE: Fuse F4 (Bypass resistor for Prestolite Alternator) must be removed for the Thermo King
Alternator.