4.3 Attaching the STP Control Unit to a Rack
The dimensions of the STP control unit front panel conform to EIA standard.
Therefore, this panel can be attached to any type of commercially-available racks.
Attach the STP control unit to the rack according to the following steps:
1) When attaching the STP control unit to a rack:
• Attach the front panel to a rack using the screw holes for the front panel.
• Also support the STP control unit from the bottom using a support angle
or a similar tool.
2) When attaching the STP control unit to a movable rack:
• Attach the front panel to a movable rack using the screw holes for the
front panel.
• To protect the STP control unit during transport, remove the rubber foot
from the bottom and attach the STP control unit to the rack using the
screw holes for the rubber foot.
◇ The STP control unit cannot be supported with only the screws on
the front panel (The STP control unit is a heavy product).
Always support it from the bottom. DO NOT block the ventilation port.
◇ For the peripheral space of the STP control unit, see Figure 4.4,
"Peripheral Space of the STP Control Unit."
◇ For the dimensions of the front panel and positions of screw holes
for the rubber foot, see Figure 16.3, "External Appearance of the STP
Control Unit."
part: Secure with screw
Support Angle
Figure 4.5 Example of Securing the STP Control Unit