Chapter 15: Appendix
15
(6) Ground terminal of a coaxial cable
This device is used to prevent communication data errors that may be caused by electrical noise on
a coaxial cable. There should only be one ground point on any single piece of coaxial cable. Provide
class D grounding to connect this device.
Coaxial cable ground terminal for Ethernet use
(7) Transceiver cable
This cable is used to connect a transceiver to a node. The transceiver cable has a D-sub 15-pin AUI
connector on both ends. The maximum length allowed is 50 m. However, we recommend keeping
the cable length to 15 m or less to prevent problems from noise. Cables with a ground terminal must
be grounded.
Transceiver cable for Ethernet use.
Node side Ground terminal Transceiver side