Seitenansicht 103
SW
No.
Bit
No.
ITEM Soft SW setting and function Factory Setting
21
2
3
4
Silent detection threshold value Used to set the threshold value of silent detection in the
answering and recording mode.
Threshold = 8 × Bit1 + 4 × Bit2 + 2 × Bit3 + 1 × Bit4
Factory setting = 8
1
0
0
0
5
6
7
8
Silent detection start time Used to set the silent detection start time in the answering
and recording mode. The time set with this switch is that
from connection of the line to silent detection start.
TIME = 8 × Bit5 + 4 × Bit6 + 2 × Bit7 + 1 × Bit8 sec
Factory setting = 8 × 0 + 4 × 1 + 2 × 0 + 1 × 1 = 5 sec
0
1
0
1
31
2
3
4
CNG detection threshold value
(AUTO, MANUAL mode)
Used to set the threshold value of CNG signal detection.
Threshold = 8 × Bit1 + 4 × Bit2 + 2 × Bit3 + 1 × Bit4
Factory setting = 7
0
1
1
1
5
6
7
8
CNG detection threshold value
(A. M. mode)
Used to set the required number of times of CNG detection
for recognition of CNG signal one time.
Threshold = 8 × Bit5 + 6 × Bit6 + 2 × Bit7 + 1 × Bit8
Factory setting = 3
0
0
1
1
41
2
Silent detection end time Used to set the silent detection end time in the answering
and recording mode. The time set with this switch is that
from the last call sound to the silent detection end.
0
1
3
4
Number of times of CNG detection
Number of times = 2 × Bit3 + 1 × Bit4 + 1
Factory setting = 2 × 1 + 1 × 0 + 1 = 3 times
1
0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Answering and recording mode
signal detection filter
Used to select the CNG signal detection filter in the
answering and recording mode.
0
5 1 Max. reception length Used to set or not to set the max. reception length of FAX
documents. When this function is enabled, a reception
length of 1.5m or above is treated as a communication
error.
0
2 Reserved 0
3 Reserved 0
4
5
Line monitor When this function is enabled, the sound of the line under
FAX session can be heard.
0
0
6 Protocol monitor (LCD) When this function is enabled, the signal name under FAX
session is displayed on the LCD in real time.
0
7
8
Protocol monitor (Report) When this function is enabled, the detailed report on
communication is provided after completion of FAX sending
or reception.
0
0
Bit No. No limit 60sec 45sec 30sec
11100
21010
1 : Type 2 0 : Type 1
1 : No limit 0 : 1.5 m
Bit No. Always ON Error Only OFF
4100
5 10
1 : ON 0 : OFF
Bit No. Always ON Error Only OFF
7100
8 10
FO-3800M
8 – 22
Seitenansicht 103