Sharp FO-2080 Spezifikationen Seite 107

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 180
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 106
SW
No.
Bit
No.
ITEM Soft SW setting and function Factory Setting
11 1 Header Used to set the header attachment to the transmitting
document.
0
2 Header in data transfer Used to set the header attachment to the transferring
document.
0
3 Training (EQM) threshold value Used to select the threshold value to judge Success/Failure
of training in reception of training.
0
4 Reserved 0
5
6
7
Non ECM error judgement
threshold value
0
1
0
8 Reserved 0
12 1
2
3
4
5
Activity Report Auto Listing time Used to set the start time of Activity Report.
Setup is made in the unit of one hour, and setup of
minutes cannot be made.
Print start time =
Bit1 × 16 + Bit2 × 8 + Bit3 × 4 + Bit4 × 2 + Bit5 hour 00
min
Set range = 0 23
Factory Setting = 00:00
0
0
0
0
0
6 Reserved 0
7 Reserved 0
8 Reserved 0
13 1 Auto recall in direct sending
transmission
Used to set whether auto recall is made similarly to
memory transmission or not when direct transmission is
failed.
0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7
8
Compression method in receving Used to set the reception enable compression system. 0
0
14 1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
15 1 Reserved 0
2 Reserved 0
3 Reserved 0
1 : Not attached 0 : Attached
1 : Not attached 0 : Attached
1 : Easy to fall back 0 : Normal
Bit 5, 6, 7 RTP RTN
000 32 64
001 16 32
010 12 24
011 8 16
100 6 12
101 4 8
1: Valid 0: Inhibited
MH, MR,
MMR
MH, MR MH, MMR MH
70 0 1 1
80 1 0 1
FO-3800M
8 – 25
Seitenansicht 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 179 180

Kommentare zu diesen Handbüchern

Keine Kommentare