Sharp FO-2080 Spezifikationen Seite 90

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 180
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 89
24
24 -7
Purpose Data clear
Function
(Purpose)
Used to clear the photoconductor drum counter.
Section Image process
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Item Counter
24 -13
Purpose Data clear
Function
(Purpose)
Used to clear the count of use (count of scanning) of
the scanner (reading) unit.
Section Optical (Image scanning)
Item Counter
25
25 -1
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the main drive
(excluding the scanner (reading) section) section.
Section DRIVE
Item Operation
Operation/
Procedure
The main motor rotates for 30 sec.
During the motor rotation, one of the following two
operations is performed depending on installation of
the developer cartridge.
1) When the developer cartridge is installed:
(The following high voltages are outputted.)
Main charger voltage
Transfer charger voltage
Developer bias voltage
2) When the developer cartridge is not installed:
The high voltage is not outputted and the main motor rotates only.
25 -10
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the scanner (writing)
motor and its control circuit.
Section Laser (Exposure)
Item Operation
Operation/
Procedure
The scanner (write) motor rotates for 30 sec.
26
26 -2
Purpose Setting
Function
(Purpose)
Used to set Enable/Disable of the SPF and the FAX
functions. (When a trouble occurs in the SPF and the
FAX section, disable those functions to allow only
copying and scanning functions.
Section ADF/RADF/UDH/SPF
Item Specifications
Operation/
Procedure
When this simulation is executed, the code of current
setup of ENABLE/DISABLE of SPF/FAX function is
displayed.
Enter the desired code number corresponding to Enable/Disable
setup and press the Start button, and the setup will be effective.
Set code number SPF/FAX function
0 Disable
1 Enable
26 -6
Purpose Setting
Function
(Purpose)
Used to set the destination.
Item Specifications
Operation/
Procedure
1) The currently set code of the destination is
displayed.
2) To change the set content, enter the code of your desired
setting and press the start button.
Destination code Detected paper size
Set
value
Destination
Paper
type
Paper width
detector ON
Paper width
detector OFF
0
Inch
series
11 8.5/
14 8.5
8.5 5.5/
8.5 11
1 EX Japan
AB
series
A4 (210
356 mm)
A5
2 Japan
AB
series
A4 (210
356 mm)
B5
When the set value is changed, the paper size specification and the
fixed, enlarged, and reduced copy magnification ratios are changed.
26 -7
Purpose Setting
Function
(Purpose)
Used to set the model (hardware) specifications.
Section PCU
Item Specifications Operation mode (Common)
Operation/
Procedure
When this simulation is executed, the monitor lamp
corresponding to the model (hardware) is displayed.
Copy quantity display Copy speed (CPM)
6 6cpm
6 8cpm
26 -20
Purpose Setting
Function
(Purpose)
Used to set the rear void area YES/NO.
Item Specifications Operation mode (Common)
Operation/
Procedure
1) The currently set code of the rear void area
YES/NO is displayed.
2) To change the set content, enter the code of your desired setting
and press the start button.
Set code Rear edge void area
0 YES
1NO
The rear edge void amount can be adjusted with SIM 50-1.
Be sure to set to "0" (Rear edge void area YES).
FO-3800M
8 – 8
Seitenansicht 89
1 2 ... 85 86 87 88 89 90 91 92 93 94 95 ... 179 180