Seitenansicht 86
(3) Details of simulations
1
1 -1
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the scanner (reading)
unit and its control circuit.
Section Optical (Image scanning)
Item Operation
Operation/
Procedure
Set the copy magnification ratio to any desired level
and press the start button. The scanner scans
(reads) once at the scanning speed corresponding to
the set copy magnification ratio.
At that time, the operation of the scanner home position sensor
(MHPS) can be checked wit the photoconductor lamp.
When the scanner is at the home position, that is, when the scanner
home position sensor (MHPS) detects the scanner, the
photoconductor lamp lights up.
2
2 -2
Purpose Operation test/check
Function
(Purpose)
Used to check the operations of the sensors and
detectors in the SPF unit and the related circuit.
Section ADF/RADF/UDH/SPF
Item Operation
Operation/
Procedure
The operating status of detectors and sensors in the
SPF unit is displayed with the lamps on the operation
panel.
Display lamp Detectors and sensors
Developing cartridge
replacement lamp
SPF original detector (SPID)
Machine jam lamp SPF original transport detector (SPPD)
SPF jam lamp SPF open/close detector (SDSW)
2 -3
Purpose Operation test/check
Function
(Purpose)
Used to check the operations of the RADF/ADF/SPF
unit motors and their control circuits.
Section ADF/RADF/UDH/SPF
Item Operation
Operation/
Procedure
When the START button is pressed, the SPF motor
rotates for 10 sec in the speed corresponding to the
set copy magnification ratio.
2 -4
Purpose Operation test/check
Function
(Purpose)
Used to check the operations of the loads (solenoids)
in the RADF/ADF/SPF units and their control circuits.
Section ADF/RADF/UDH/SPF
Item Operation
Operation/
Procedure
When the START button is pressed, the SPF paper
feed solenoid (SPUS) repeats ON (500ms) and OFF
(500ms) 20 times.
5
5 -1
Purpose Operation test/check
Function
(Purpose)
Used to check the operations of the operation panel
display lamps and their control circuits.
Section Operation (Display/Operation key)
Item Operation
Operation/
Procedure
When the START button is pressed, the all lamps on
the LCD are lighted and the total LCD display is
made simultaneously.
5 -2
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the heater lamp and
its control circuit. Used to check the operation of the
fan motor and its control circuit.
Section Fixing (Fusing)
Item Operation
Operation/
Procedure
The heater lamp repeat ON for 500msec and OFF for
500msec each 5 times.
During this time, the fan motor rotates.
5 -3
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the copy lamp and its
control circuit.
Section Optical (Image scanning)
Item Operation
Operation/
Procedure
The copy lamp is lighted for 5 sec.
6
6 -1
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the paper feed
(clutch, solenoid and its control circuit.
Section Paper transport
Item Operation
Operation/
Procedure
The paper feed clutch solenoid repeats ON for
500msec and OFF for 500msec each 20 times.
FO-3800M