Sharp FO-2080 Spezifikationen Seite 78

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 180
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 77
ADJ 1
Charging (main charger) voltage
adjustment
Adjustment value
Range (MIN) –1050 V
Range (MAX) –1200 V
Standard value –1100 V
Default –1100 V
Program used
Test command (Simulation) MODE Normal
MAIN CODE 8
SUB CODE 2
Execution condition (time)
Enforcement
time
JOB No Content
S 009/Ua 004 When replacing the High
voltage/motor drive PWB unit
Cycle
Condition Print (copy) density is too dark
or too light. Though copy
density adjustment is executed
with the Test command
(simulation) 46-1, satisfactory
denstiy cannot be obtained.
Work content
1) Connect between the power PWB and the MCU PWB, the high
voltage/motor drive PWB unit and the operation unit with har-
nesses.
2) Manually turn on the cover switch and turn on the power.
3) Execute SIM 8-2. (The charging voltage (main charer) is out-
putted.)
4) Measure the charging (main charger) voltage with a digital multi-
meter (effective value meter, input impednce 1000M or above).
Adjust VR801 so that the output voltage is –1050 –1200 V.
Before measurement, connect the capacitor and the diode to the
tip of the digital multi-metar as shown below.
Troubles caused by improper work
1) Copy (print) defective (Insufficient density, background copy, dirt,
etc.)
2) The copy density cannot be adjusted in the proper range with SIM
46-1.
3) The photoconductor is damaged.
After-work
JOB No. Content
ADJ M1 Copy density adjustment
Necessary tools
Name Digital multi-meter/High voltage probe
Parts code/Price rank
Note Internal impedance 1000 or above,
effective value measurement
Recommendable unit:
(FLUKE 87/FLUKE 80K-40)
Name Diode
Parts code/Price rank VHDSV03///-1
Note Other type withstand voltage of 2KV or
above can be used instead.
Name Capacitor
Parts code/Price rank VCKYQ3FB102K
Note Other type withstand voltage of 3KV with
1000pF can be used instead.
Note
1) Use a digital multi-meter (effective value meter, internal im-
pedance of 1000M or above).
Connect the capacitor and the diode to the tip of the digital multi-
meter for measurement. If the above condition are not satisfied,
the proper measurement of voltage cannot be made.
2) Since a high voltage is outputted, be careful of electric shock.
FO-3800M
7 – 16
Seitenansicht 77